首页> 外文期刊>Industrial and organizational psychology >A prototype open-ended multichannel intracavitary-interstitial hybrid applicator for gynecological high-dose-rate brachytherapy
【24h】

A prototype open-ended multichannel intracavitary-interstitial hybrid applicator for gynecological high-dose-rate brachytherapy

机译:用于妇科高剂量速率近距离放射治疗的原型开放式多通道内腔内间隙涂药器

获取原文
获取原文并翻译 | 示例
           

摘要

This manuscript introduces a novel open-ended, multichannel intracavitary-interstitial hybrid applicator for gynecological high-dose-rate brachytherapy. A prototype was three-dimensionally (3D) printed using polylactic acid. The device was 25 mm in diameter and 150 mm in length, with eight evenly spaced peripheral channels around a central tandem channel, each 2.7 mm in diameter and with 2 mm source-to-cylinder-surface-distance. In contrast to conventional multichannel applicators, the new hybrid applicator was designed with open distal ends. Interstitial needles utilized in peripheral channels provided a closed environment for sources. The applicator body served as a template to aid in the placement of central tandem and peripheral needles. The physical prototype appropriately accommodated needles, tandem, and locking devices and, thus, was deemed magnetic resonance (MR) conditional. In our retrospective in silico studies of two representative prior patients, we simultaneously increased the target coverage and decreased the organ-at-risk (OAR) dose to 2 cc (D-2cc). Specifically, the minimum dose covering 90% of the volume (D-90%) was improved by 2.1% (9.2%) minimum (maximum) of the prescription dose. Additionally, the OAR D-2cc was decreased by 0.5% (4.5%), 8.2% (12.9%), 3.9% (9.2%), and 4.6% (19.8%) minimum (maximum) of the prescription dose to the sigmoid, bladder, rectum, and bowel, respectively. This prototype demonstrated significant potential for patients in whom it would be useful to provide multichannel capabilities beyond the applicator body.
机译:这款手稿介绍了一种新颖的开放式多通道内腔内间质杂交杂交涂抹器,用于妇科高剂量速率近距离放射治疗。使用聚乳酸印刷三维(3D)原型。该装置直径为25毫米,长度为150毫米,围绕中心串联通道围绕八个均匀间隔的外围通道,直径2.7毫米,具有2毫米的源极距离。与传统的多通道涂敷器相比,新的混合动力涂抹器设计有开口远端。外围通道中使用的间隙针提供了封闭环境的来源。涂抹器体用作模板,以帮助放置中央串联和外围针。物理原型适当地容纳针头,串联和锁定装置,因此被认为是磁共振(MR)条件。在我们对两名代表性患者的三种研究的回顾下,我们同时增加了目标覆盖率并降低了器官风险(OAR)剂量至2cc(d-2cc)。具体地,覆盖90%的体积(D-90%)的最小剂量得到5.1%(9.2%)的处方剂量(最大值)。此外,OAR D-2CC减少0.5%(4.5%),8.2%(12.9%),3.9%(9.2%)和4.6%(最大)的4.6%(最大)对乙状剂量,分别膀胱,直肠和肠道。该原型对提供超出涂抹机体内的多通道能力有用的患者表现出显着的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号