首页> 外文期刊>Applied optics >Quantization analysis of speckle intensity measurements for phase retrieval
【24h】

Quantization analysis of speckle intensity measurements for phase retrieval

机译:斑点强度测量的量化分析,用于相位恢复

获取原文
获取原文并翻译 | 示例
           

摘要

Speckle intensity measurements utilized for phase retrieval (PR) are sequentially taken with a digital camera, which introduces quantization error that diminishes the signal quality. Influences of quantization on the speckle intensity distribution and PR are investigated numerically and experimentally in the static wavefront sensing setup. Results show that 3 to 4 bits are adequate to represent the speckle intensities and yield acceptable reconstructions at relatively fast convergence rates. Computer memory requirements may be eased down by 2.4 times if a 4 bit instead of an 8 bit camera is used. This may facilitate rapid speckle data acquisition for dynamic wavefront sensing.
机译:用于相位恢复(PR)的斑点强度测量是使用数码相机顺序进行的,该相机会引入量化误差,从而降低信号质量。在静态波前传感装置中,通过数值和实验研究了量化对斑点强度分布和PR的影响。结果表明,3到4位足以表示散斑强度,并且可以在相对较快的收敛速度下产生可接受的重构。如果使用4位而不是8位相机,则计算机内存需求可能会降低2.4倍。这可以促进用于动态波前感测的快速散斑数据获取。