...
首页> 外文期刊>Applied optics >Performance of a FieldSpec spectroradiometer for aerosol optical depth retrieval: method and preliminary results
【24h】

Performance of a FieldSpec spectroradiometer for aerosol optical depth retrieval: method and preliminary results

机译:FieldSpec光谱辐射仪用于气溶胶光学深度检索的性能:方法和初步结果

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The performance of a FieldSpec spectroradiometer for retrieving aerosol optical depth (AOD) has been assessed after modifying its basic configuration in order to measure direct solar irradiance at ground level. The FieldSpec measurements were obtained during four summertime days in the years 2004 and 2005, over a Spanish agricultural site in Barrax, Albacete (30 deg 3 min N, 2 deg 6 min W, 700 m a.s.l.), in the framework of two European Space Agency mission remote sensing field campaigns. From the whole FieldSpec spectral domain (350 - 2500 nm) the AOD was extracted for channels within atmospheric windows. The instrument was calibrated by means of the standard Langley plot method, performed at a high mountain site in Italy. The AOD retrieved by the FieldSpec has been validated by comparison with the AOD obtained from a colocated CIMEL CE318 Sun photometer. The FieldSpec AOD spectra were convoluted with the CE318 filter transmission functions in order to make both datasets comparable. Our results show that both datasets are very similar (R~(2) around 0.9) for all the channels from the CE318, with an average deviation of about 0.02. The temporal evolution of the AOD was accurately monitored by the FieldSpec under different atmospheric conditions, as was the case for a previously reported mineral dust intrusion. As a conclusion, the comparison performed in this study shows that the FieldSpec spectro-radiometer is a suitable instrument for retrieving the AOD in different atmospheric situations.
机译:在修改其基本配置以便在地面上测量直接太阳辐照度之后,已经对FieldSpec光谱辐射仪的气溶胶光学深度(AOD)检索性能进行了评估。 FieldSpec测量值是在2004年和2005年的四个夏季天期间,在阿尔巴塞特的Barrax的一个西班牙农业站点上获得的(北纬30度3分,西经2度6分,海拔700 m,在两个欧洲空间框架内)机构任务遥感野外活动。从整个FieldSpec光谱域(350-2500 nm)中,提取大气窗口内通道的AOD。该仪器通过标准的兰利绘图法进行了校准,该方法在意大利的一个高山地区进行。通过与从共置的CIMEL CE318 Sun光度计获得的AOD进行比较,已验证了FieldSpec检索到的AOD。为了使两个数据集具有可比性,FieldSpec AOD光谱与CE318滤波器的透射函数进行了卷积。我们的结果表明,对于来自CE318的所有通道,两个数据集都非常相似(R〜(2)约为0.9),平均偏差约为0.02。通过FieldSpec在不同的大气条件下可以准确地监控AOD的时间演变,就像以前报道的矿物粉尘入侵一样。总之,本研究进行的比较表明,FieldSpec分光辐射仪是在不同大气情况下获取AOD的合适仪器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号