The aim of this study was to compare density heterogeneity on wide volume (WV) scans with that on helical CT scans. 22 subjects underwent chest CT using 320-WV and 64-helical modes. Density heterogeneity of the descending aorta was evaluated quantitatively and qualitatively. At qualitative assessment, the heterogeneity was judged to be smaller on WV scans than on helical scans ( p<. 0.0001). Mean changes in aortic density between two contiguous slices were 1.64. HU (3.40%) on WV scans and 2.29. HU (5.19%) on helical scans ( p< 0.0001). CT density of thoracic organs is more homogeneous and reliable on WV scans than on helical scans.
机译:这项研究的目的是比较宽体积(WV)扫描和螺旋CT扫描的密度异质性。 22位受试者使用320 WV和64螺旋模式进行了胸部CT检查。定量和定性评估降主动脉的密度异质性。在定性评估中,WV扫描的异质性被判定为小于螺旋扫描的异质性(p <0.0001)。两个连续切片之间的主动脉密度平均变化为1.64。 HU(3.40%)的WV扫描和2.29。螺旋扫描的HU(5.19%)(p <0.0001)。与螺旋扫描相比,在WV扫描中,胸腔器官的CT密度更均匀,更可靠。