The implantable cardioverter-defibrillator (ICD) is an effective therapeutic device for rescuing patients with cardiac diseases from death caused by life-threatening arrhythmias. The authors previously have proposed a detection algorithm of life-threatening arrhythmia with a multiple regression model. In this research, we have developed the algorithm so as to accurately classify cardiac rhythms and to reduce in the computational time with a microcontroller used in the ICD. The experimental results showed that the proposed method kept a high accuracy to detect cardiac rhythms. In addition, the validation of implementation of the proposed algorithm in the microcontroller indicated that the result of detection of cardiac rhythms could be attained within computational time of 60 ms. For the practical application, it is necessary to evaluate the power consumption of the ICD working with the proposed method.
机译:植入式心脏复律除颤器(ICD)是一种有效的治疗设备,可挽救患有威胁生命的心律不齐导致的心脏病患者死亡。作者先前已经提出了具有多元回归模型的威胁生命的心律失常的检测算法。在这项研究中,我们开发了该算法,以便使用ICD中使用的微控制器准确地对心律进行分类并减少计算时间。实验结果表明,该方法具有较高的心律检测精度。另外,在微控制器中对所提出算法的实现的验证表明,可以在60 ms的计算时间内获得心律的检测结果。对于实际应用,有必要使用所提出的方法评估ICD的功耗。