The concentrations of hepatitis C virus (HCV) are reported to be lower in dialysis patients than those in HCV-positive non-dialysis patients. In order to explain this clinical view, we modeled the adsorption phenomenon of the HCV antigen in the dialysis membrane surface with the Langmuir's adsorption isotherm, and proposed the mathematical model in consideration of the adsorption effect of HCV by the dialysis membrane. Therefore we conducted the recirculation experiment with various dialysis membrane in vitro system, and conducted curve fitting based on that result in order to examine the validity of this model. We perfused albumin (Alb) solution containing HCV and physiological salt solution containing HCV in the blood circuit connected to a regenerated cellulose (CU) membrane, cellulose triacetate (CTA) membrane, polymethylmethacrylate (PMMA) membrane, or polysulfone (PS) membrane, and measured quantities of HCV antigen and Alb over time. Further to consider the effect of Alb on the dialysis membrane, we analyzed the quantity of adsorption of the HCV antigen under Alb mixture and under Alb free in each dialysis membrane, and calculated the coefficient of adsorption rate and the quantity of the maximum adsorption of the HCV antigen for every dialysis membrane. The quantity of HCV antigen adsorption by PS membrane was 26.8 fmol under Alb solution and 29.0 fmol under physiological salt solution, was the maximum rather than other dialysis membranes, and the coefficient of adsorption rate was the fastest with PS membrane. In conclusion, the usefulness of the model which we created was suggested and we determined the useful dialysis membrane as reduction of the amount of HCV antigens in HCV-positive dialysis patients.
机译:据报道,透析患者中​​丙型肝炎病毒(HCV)的浓度低于HCV阳性非透析患者。为了解释该临床观点,我们用Langmuir的吸附等温线模拟了HCV抗原在透析膜表面的吸附现象,并提出了考虑到透析膜对HCV的吸附作用的数学模型。因此,我们在体外用各种透析膜进行了再循环实验,并基于该结果进行了曲线拟合,以检验该模型的有效性。我们在与再生纤维素(CU)膜,三乙酸纤维素(CTA)膜,聚甲基丙烯酸甲酯(PMMA)膜或聚砜(PS)膜相连的血液回路中灌注了含有HCV的白蛋白(Alb)溶液和含有HCV的生理盐溶液。随时间测量HCV抗原和Alb的量。为了进一步考虑Alb对透析膜的影响,我们分析了在每个透析膜中Alb混合物和不含Alb的混合物中HCV抗原的吸附量,并计算了吸附速率系数和最大吸附量。 HCV抗原用于每个透析膜。 PS膜对HCV抗原的吸附量在Alb溶液下为26.8 fmol,在生理盐溶液下为29.0 fmol,是最大的,而不是其他透析膜,PS膜的吸附速率系数最快。总之,提出了我们创建的模型的有用性,并且我们确定了有用的透析膜可以减少HCV阳性透析患者中​​HCV抗原的数量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号