首页> 外文期刊>材料と環境 >Using Meteorological Data to Evaluate Atmospheric Corrosivity for Stainless Steels
【24h】

Using Meteorological Data to Evaluate Atmospheric Corrosivity for Stainless Steels

机译:使用气象数据评估不锈钢的大气腐蚀性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The Makuhari-Messe Convention Center is located in a coastal area, 500 m from the sea, in Chiba city, Chiba prefecture (Honshu). Its roof and eaves are made of 22Cr-0.8Mo stainless steel. To evaluate the corrosivity of the atmosphere beneath the eaves, atmospheric corrosion monitor (ACM) sensors and 22Cr-0.8Mo steel specimens were exposed at five points on the building: sites 1 and 2 were on its southwestern side (side A), facing toward the sea, and sites 3, 4 and 5 were on the northeastern side (side B), facing away from the sea. The sensors were installed in November 1994 and renewed every 1-4 months until November 1996. Sensor output was measured every 10 minutes, together with temperature and relative humidity (RH). The amount of deposited seasalt (W_s) was also measured, based on sensor output combined with RH data. The 22Cr-0.8Mo steel specimens only rusted at sites 1 and 2, and then only during a single exposure period, from April 19, 1995 to June 22, 1995, when W_s increased to more than 1 g/m~2. The exact day when W_s exceeded 1 g/cm~2 and the steel rusted was identified based on the effective coefficient of daily wind-force energy (#alpha#_D~*).
机译:幕张国际会展中心位于千叶县(本州)千叶市,距海边500 m。它的屋顶和屋檐由22Cr-0.8Mo不锈钢制成。为了评估屋檐下大气的腐蚀性,大气腐蚀监测器(ACM)传感器和22Cr-0.8Mo钢样本在建筑物的五个位置暴露:位置1和2位于其西南侧(A面),朝向海洋,地点3、4和5位于东北侧(B面),背对大海。传感器于1994年11月安装,每1-4个月更新一次,直到1996年11月为止。传感器的输出每10分钟测量一次,并测量温度和相对湿度(RH)。基于传感器输出和RH数据,还测量了沉积海盐(W_s)的量。从1995年4月19日至1995年6月22日,当W_s增至1 g / m〜2以上时,22Cr-0.8Mo钢试样仅在站点1和2生锈,然后仅在一个暴露期生锈。根据每日风力能量的有效系数(#alpha#_D〜*)确定W_s超过1 g / cm〜2且钢铁生锈的确切日期。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号