摘要

The protective ability of rust layers formed on weathering steels exposed in an industrial region for various periods has been studied by potential measurement, and rust composition and structure were also studied. The potential of weathering steel in 0.1 mol/L Na_2SO_4 solution tends to become noble with exposure time. The potential of weathering steels with rust layers, which were exposed for a long time and had superior atmospheric corrosion resistance, was over - 0.3 V (vs. SCE). The rust layer possesses a double-layer structure composed of an inner dark layer of #alpha#'-FeOOH and an outer bright layer under reflected polarized light, which is observed typically in a protective rust layer. On the other hand, the potential of mild steel exposed for a long time is less noble at about -0.45 V (vs. SCE). These results mean that the potential reflects the different characteristics of the rust layer. The potential becomes noble with increasing amount of #alpha# FeOOH in rust, which suggests that it depends on the composition of the rust layer. Furthermore, the potential correlates with the ratio of rust composition #alpha#/#gamma#~*: #alpha#-FeOOH/(#gamma#-FeOOH+, 8-FeOOH+ Fe_3O_4), and the potential of -0.3V (vs. SCE) corresponds to #alpha#/#gamma#~*=2.Therefore the potential as well as the ratio #alpha#/#gamma#~* can be used to evaluate the protective ability of the rust layers formed on weathering steels.
机译:通过电势测量研究了工业区暴露于不同时间的耐候钢上形成的锈层的保护能力,并研究了锈的成分和结构。 0.1 mol / L Na_2SO_4溶液中耐候钢的电位随暴露时间而趋于变高。长时间暴露且具有优异的耐大气腐蚀性能的带锈层的耐候钢的电势超过-0.3 V(vs. SCE)。防锈层具有双层结构,该双层结构由#alpha#'-FeOOH的内部暗层和反射偏振光下的外部亮层组成,通常在保护性防锈层中观察到。另一方面,在-0.45 V(vs. SCE)下,长时间暴露的低碳钢的电位较低。这些结果意味着电势反映了防锈层的不同特性。随着铁锈中#alpha#FeOOH含量的增加,电势变高,这表明它取决于铁锈层的组成。此外,电势与铁锈组成#alpha#/#gamma#〜*:#alpha#-FeOOH /(#gamma#-FeOOH +,8-FeOOH + Fe_3O_4)的比率以及-0.3V(vs. SCE)对应于#alpha#/#gamma#〜* = 2,因此电势和比例#alpha#/#gamma#〜*可用于评估在耐候钢上形成的防锈层的防护能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号