Functional MRI using multiple receiver coils: BOLD signal changes and signal-to-noise ratio for three-dimensional-PRESTO vs. single shot EPI in comparison to a standard quadrature head coil.

机译:使用多个接收器线圈的功能MRI:与标准的正交头线圈相比,三维PRESTO与单次EPI相比,BOLD信号变化和信噪比更高。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare the performance of single shot echo planar imaging (SSEPI) with three-dimensional-multishot echo-planar imaging (EPI) based on principles-of-echo-shifting-with-a-train-of-observations (PRESTO) in combination with a standard quadrature head coil and, as an alternative, a multiple receiver coil in intraoperative functional magnetic resonance imaging (fMRI). MATERIALS AND METHODS: Six healthy subjects underwent fMRI with visual stimulation using a SSEPI and a PRESTO-sequence with both coil systems. Statistical evaluation was done with a scanner-based post-processing software and SPM 99. The number of activated voxels in the visual cortex, the percent signal change between rest and activation, and finally the signal-to-noise ratio (SNR) during time course were measured and compared for both coil systems and both sequences, used in four different combinations. RESULTS: Blood oxygen level dependent (BOLD) signal changes were the lowest with PRESTO and standard head coil and the highest for SSEPI and phased array coil. For the latter combination, a significantly higher signal change and larger activation size was observed together with a better SNR. SSEPI yielded similar performance using both coils. CONCLUSION: SSEPI was superior due to its better SNR and a higher BOLD signal change in the defined settings, irrespective of the coil used. In a stereotactical setup the phased array coil can be used to generate fMRI data without loss of image quality.
机译:目的:比较单次回波平面成像(SSEPI)和三维多镜头回波平面成像(EPI)的性能,该方法基于观测序列的回波平移原理(PRESTO)在手术中功能磁共振成像(fMRI)中与标准的正交头线圈以及作为替代方案的多接收器线圈结合使用。材料与方法:六名健康受试者在两个线圈系统中使用SSEPI和PRESTO序列进行了视觉刺激下的功能性磁共振成像。使用基于扫描仪的后处理软件和SPM 99进行统计评估。视觉皮层中已激活体素的数量,静止与激活之间的信号变化百分比,最后是一段时间内的信噪比(SNR)。测量了线圈系统和两个序列的航向并进行了比较,以四种不同的组合使用。结果:血氧水平依赖性(BOLD)信号变化在PRESTO和标准头线圈中最低,而在SSEPI和相控阵线圈中最高。对于后一种组合,观察到明显更高的信号变化和更大的激活大小以及更好的SNR。使用两个线圈,SSEPI的性能相似。结论:SSEPI具有优越的信噪比,因为它在定义的设置中具有更好的SNR和更高的BOLD信号变化,而与所使用的线圈无关。在立体定向设置中,相控阵线圈可用于生成功能磁共振成像数据,而不会降低图像质量。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号