A Computer-Aided Diagnosis System for Measuring Carotid Artery Intima-Media Thickness (IMT) Using Quaternion Vectors

机译:使用四元数向量测量颈动脉内膜中膜厚度(IMT)的计算机辅助诊断系统

获取原文
获取原文并翻译 | 示例
           

摘要

This study aims investigating adjustable distant fuzzy c-means segmentation on carotid Doppler images, as well as quaternion-based convolution filters and saliency mapping procedures. We developed imaging software that will simplify the measurement of carotid artery intima-media thickness (IMT) on saliency mapping images. Additionally, specialists evaluated the present images and compared them with saliency mapping images. In the present research, we conducted imaging studies of 25 carotid Doppler images obtained by the Department of Cardiology at Firat University. After implementing fuzzy c-means segmentation and quaternion-based convolution on all Doppler images, we obtained a model that can be analyzed easily by the doctors using a bottom-up saliency model. These methods were applied to 25 carotid Doppler images and then interpreted by specialists. In the present study, we used color-filtering methods to obtain carotid color images. Saliency mapping was performed on the obtained images, and the carotid artery IMT was detected and interpreted on the obtained images from both methods and the raw images are shown in Results. Also these results were investigated by using Mean Square Error (MSE) for the raw IMT images and the method which gives the best performance is the Quaternion Based Saliency Mapping (QBSM). 0,0014 and 0,000191 mm(2) MSEs were obtained for artery lumen diameters and plaque diameters in carotid arteries respectively. We found that computer-based image processing methods used on carotid Doppler could aid doctors' in their decision-making process. We developed software that could ease the process of measuring carotid IMT for cardiologists and help them to evaluate their findings.
机译:这项研究旨在调查颈动脉多普勒图像上的可调远距离模糊c均值分割,以及基于四元数的卷积滤波器和显着性映射程序。我们开发了成像软件,可以简化在显着性成像图像上测量颈动脉内膜中层厚度(IMT)的过程。此外,专家评估了当前图像并将其与显着性映射图像进行了比较。在本研究中,我们对由Firat大学心脏病系获得的25例颈动脉多普勒图像进行了成像研究。在所有多普勒图像上执行模糊c均值分割和基于四元数的卷积后,我们获得了一个可以由医生使用自下而上的显着性模型轻松分析的模型。这些方法应用于25个颈动脉多普勒图像,然后由专家进行解释。在本研究中,我们使用颜色过滤方法来获得颈动脉彩色图像。对获得的图像进行显着性映射,并通过两种方法在获得的图像上检测并解释颈动脉IMT,结果显示原始图像。这些结果还通过对原始IMT图像使用均方误差(MSE)进行了研究,而性能最佳的方法是基于四元数的显着性映射(QBSM)。 0,0014和0,000191 mm(2)MSE分别获得了颈动脉的动脉管腔直径和斑块直径。我们发现在颈动脉多普勒上使用的基于计算机的图像处理方法可以帮助医生进行决策。我们开发了可以简化心脏病专家测量颈动脉IMT的过程的软件,并帮助他们评估他们的发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号