首页> 外文期刊>Journal of medical systems >Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension
【24h】

Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension

机译:基于脉搏到达时间的袖带减少和24小时可穿戴血压监测及其对高血压的诊断价值

获取原文
获取原文并翻译 | 示例
           

摘要

Ambulatory blood pressure monitoring (ABPM) has become an essential tool in the diagnosis and management of hypertension. Current standard ABPM devices use an oscillometric cuff-based method which can cause physical discomfort to the patients with repeated inflations and deflations, especially during nighttime leading to sleep disturbance. The ability to measure ambulatory BP accurately and comfortably without a cuff would be attractive. This study validated the accuracy of a cuff-less approach for ABPM using pulse arrival time (PAT) measurements on both healthy and hypertensive subjects for potential use in hypertensive management, which is the first of its kind. The wearable cuff-less device was evaluated against a standard cuff-based device on 24 subjects of which 15 have known hypertension. BP measurements were taken from each subject over a 24-h period by the cuffless and cuff-based devices every 15 to 30 minutes during daily activities. Mean BP of each subject during daytime, nighttime and over 24-h were calculated. Agreement between mean nighttime systolic BP (SBP) and diastolic (DBP) measured by the two devices evaluated using Bland-Altman plot were -1.4 +/- 6.6 and 0.4 +/- 6.7 mmHg, respectively. Receiver operator characteristics (ROC) statistics was used to assess the diagnostic accuracy of the cuff-less approach in the detection of BP above the hypertension threshold during nighttime (> 120/70 mmHg). The area under ROC curves were 0.975/0.79 for nighttime. The results suggest that PAT-based approach is accurate and promising for ABPM without the issue of sleep disturbances associated with cuff-based devices.
机译:动态血压监测(ABPM)已成为诊断和管理高血压的重要工具。当前的标准ABPM设备使用基于示波法的袖带法,这种方法会给患者造成反复不适和不适,特别是在夜间导致睡眠障碍的情况下。无需袖带即可准确舒适地测量动态血压的能力将很有吸引力。这项研究使用健康和高血压受试者的脉搏到达时间(PAT)测量结果验证了ABPM无袖方法的准确性,这可能是首次在高血压管理中使用。在标准的基于袖带的设备上对24名受试者进行了可穿戴式无袖带设备的评估,其中15名患有高血压。在日常活动中,每隔15至30分钟用无袖套和基于袖套的设备在24小时内对每个受试者进行BP测量。计算白天,夜间和24小时以上的每个受试者的平均血压。使用Bland-Altman图评估的两种设备测得的平均夜间收缩压(SBP)和舒张压(DBP)之间的一致性分别为-1.4 +/- 6.6和0.4 +/- 6.7 mmHg。接收者操作员特征(ROC)统计数据用于评估无袖套方法在夜间(> 120/70 mmHg)高于高血压阈值的BP检测中的诊断准确性。夜间ROC曲线下的面积为0.975 / 0.79。结果表明,基于PAT的方法对于ABPM是准确且有希望的,而不会出现与基于袖带的设备相关的睡眠障碍问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号