...
首页> 外文期刊>Journal of hand therapy: Official journal of the American Society of Hand Therapists >A torque-controlled device to measure passive abduction of the thumb carpometacarpal joint.
【24h】

A torque-controlled device to measure passive abduction of the thumb carpometacarpal joint.

机译:扭矩控制装置,用于测量拇指掌指关节的被动外展。

获取原文
获取原文并翻译 | 示例
           

摘要

The primary aim of this study was to design and then test the intrarater reliability of a torque-controlled method of measuring passive abduction of the thumb carpometacarpal (CMC) joint. A secondary aim was to quantify passive CMC abduction in patients with and without contracture. Initially, clinicians used subjective feel (without range of motion measurements) to identify 52 people with loss of passive thumb CMC abduction. All subjects had a neurological condition. Passive thumb CMC abduction was measured in both hands of these 52 people and the hands of another 20 healthy able-bodied individuals (total of 72 people and 144 hands). Passive thumb CMC abduction was measured using a newly designed torque-controlled device and the previously recommended caliper method. Repeat measurements were taken with both devices, two to three days later, by blinded assessors on a subgroup of 12 patients (24 hands). Median (interquartile range) CMC angle of thumbs deemed by clinicians to have contracture was 45 degrees (41-52 degrees) and that of subjects without contractures was 56 degrees (53-60 degrees). The intraclass correlation coefficient for the repeat measures attained with the torque-controlled device was 0.78 (95% confidence interval, 0.56-0.90). The torque-controlled device provides a way of standardizing torque when measuring passive thumb CMC abduction. The clear difference between passive CMC abduction of subjects with and without contracture confirms the ability of clinicians to use feel and subjective assessment to identify patients with contracture.
机译:这项研究的主要目的是设计,然后测试扭矩控制方法测量拇指腕掌(CMC)关节被动外展的评估者内部可靠性。第二个目的是量化患有和不患有挛缩症患者的被动CMC绑架情况。最初,临床医生使用主观感觉(无运动测量范围)来识别52名被动拇指CMC外展丧失的患者。所有受试者都有神经系统疾病。在这52个人的双手和另外20个健康健全的人的手中(共72人和144手)测量了被动拇指CMC绑架。使用新设计的扭矩控制设备和先前推荐的卡尺方法测量被动拇指CMC外展。两到三天后,由盲人评估者对这组12位患者(24手)的亚组使用这两种设备进行重复测量。临床医生认为患有挛缩症的中位(四分位间距)CMC拇指角为45度(41-52度),没有挛缩的受试者的CMC拇指角为56度(53-60度)。使用扭矩控制设备获得的重复测量的组内相关系数为0.78(95%置信区间为0.56-0.90)。当测量被动拇指CMC外展时,扭矩控制设备提供了一种标准化扭矩的方法。患有和未患有挛缩症的受试者的被动CMC绑架之间的明显区别证实了临床医生具有使用感觉和主观评估来鉴定患有挛缩症的患者的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号