首页> 外文期刊>Clinical biomechanics >Reproducibility of hand-held ankle dynamometry to measure altered ankle moment-angle characteristics in children with spastic cerebral palsy.
【24h】

Reproducibility of hand-held ankle dynamometry to measure altered ankle moment-angle characteristics in children with spastic cerebral palsy.

机译:手持式脚踝测力计可测量痉挛性脑瘫患儿改变的踝力矩角特性。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: In children with spastic cerebral palsy, the range of motion of the ankle joint is often limited. Measurement of range of motion may be hampered by a non-rigid foot deformity. We constructed a hand-held instrument which allows measurements of static ankle angle and moment in children with cerebral palsy while correcting for foot deformity. This study aimed to test the reproducibility of the instrument and to use it for measuring ankle moment-angle characteristics in individual children who are typically developing and children with cerebral palsy. METHODS: Ankle angles and moments were measured at five standardized positions in ten children who are typically developing and ten children with cerebral palsy. The intraclass correlation coefficient was calculated for test-retest reliability. For precision, the standard error of measurement and smallest detectable difference were determined. The ankle range of motion and the slope of the moment-angle curve were determined, both towards plantar flexion and dorsiflexion. FINDINGS: The reproducibility study revealed a high reliability of the dynamometer at 5 repetitions (>0.97). Precision lies within 5 degrees for angle measurements and within 0.2 Nm for moment measurements. In the children with cerebral palsy, the range of motion towards dorsiflexion was 18 degrees lower and the slope of the moment-angle curve towards dorsiflexion was substantially higher. INTERPRETATION: We developed a hand-held dynamometer which allows reliable and precise measurements of static ankle angle and moment in children with cerebral palsy. The hand-held dynamometer allows corrections of foot deformities and is qualified to reproducibly evaluate moment-angle characteristics in a clinical context.
机译:背景:在患有痉挛性脑瘫的儿童中,踝关节的运动范围通常受到限制。运动范围的测量可能会因非刚性足部畸形而受阻。我们构造了一种手持式仪器,可以测量患有脑瘫的儿童的静态脚踝角度和力矩,同时校正脚部畸形。这项研究旨在测试该仪器的可再现性,并将其用于测量典型发育中的儿童和脑瘫儿童的踝力矩角特性。方法:在十个典型的发育中儿童和十个脑瘫儿童中,在五个标准化位置测量踝关节的角度和力矩。计算组内相关系数以实现重测信度。为了精度,确定了标准的测量误差和最小的可检测差异。确定了脚踝的运动范围和力矩角曲线的斜率,都朝向plant屈和背屈。结果:再现性研究表明,测功机在5次重复测试(> 0.97)时具有很高的可靠性。角度测量的精度在5度以内,力矩测量的精度在0.2 Nm以内。在患有脑瘫的儿童中,背屈运动范围降低了18度,力矩角曲线向背屈运动的斜率大大提高了。解释:我们开发了一种手持式测力计,可以对脑瘫患儿的静态踝角和力矩进行可靠而精确的测量。手持式测功机可以矫正足部畸形,并具有在临床环境中可重复评估弯矩角特性的资格。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号