Anterior cervical decompression and fusion is most successful when bone graft is combined with stabilizing instrumentation. The use of bioresorbable anterior cervical plates has been reported recently instead of the traditional titanium plate. We report a novel application of a bioresorbable plate in the management of a 69-year-old Caucasian female with multi-level, long-standing cervical spondylotic myelopathy. The patient previously had a failed anterior fusion with allograft and titanium instrumentation, and due to worsening symptoms, she underwent a revision anterior fusion using a bioresorbable cervical plate and a fibular allograft, in conjunction with posterior fusion with metal instrumentation. Successful fusion is visualized on CT imaging at 8-year follow-up. To our knowledge this is the first report of long-term follow-up showing successful fusion with this technology.
机译:当植骨与稳定器械相结合时,颈椎前路减压和融合最为成功。最近已有报道使用可生物吸收的前颈椎板代替传统的钛板。我们报告生物吸收板在多级,长期颈椎病脊髓病的69岁白种女性的管理中的新型应用。该患者先前的同种异体植骨和钛器械融合失败,并且由于症状恶化,她使用可生物吸收的颈椎板和腓骨同种异体骨联合后路融合融合术与金属器械进行了前路融合术。在8年的随访中,CT成像显示成功融合。据我们所知,这是长期随访的第一份报告,显示该技术已成功融合。