OBJECTIVE: To assess the efficacy of a device using extraocular electrodes as a retinal prosthesis by evaluating the responses evoked in the visual cortex to electrical stimulation. METHODS: In anaesthetised cats, a lateral orbital dissection and ipsilateral parietal craniotomy was performed. Two extraocular retinal prosthesis (ERP) disc electrodes were sutured to the sclera on the lateral and superior aspects of the globe. Retinal stimulation was performed with charge-balanced constant-current pulses. Potentials evoked in the visual cortex were measured with a ball electrode placed on the lateral gyrus after removal of the dura. RESULTS: Stable attachment of the ERP electrodes to the globe was achieved with scleral sutures. Visual cortex responses were recorded with the electrodes in bipolar and monopolar configurations. The evoked response consisted of an early component with a peak around 8 ms, and a late component with a peak after 50 ms. Thresholds for evoking a response occurred at current intensities as low as 500 microA. Through extrapolation from evoked response amplitude data, thresholds as low as 300 microA were calculated. Cathodal monopolar stimulation demonstrated lower thresholds than anodal stimulation for evoking cortical responses. CONCLUSIONS: The ERP electrodes can be easily attached to the globe and are effective in electrically stimulating the retina, evoking responses in the primary visual cortex. Threshold charge-density was within safe limits for neural stimulation.
机译:目的:通过评估视觉皮层引起的对电刺激的反应,评估使用眼外电极作为视网膜假体的器械的功效。方法:在麻醉的猫中,进行眼眶外侧解剖和同侧顶叶颅骨切开术。将两个眼外视网膜假体(ERP)椎间盘电极缝合到球囊的外侧和上方。用电荷平衡恒流脉冲进行视网膜刺激。去除硬脑膜后,用放置在外侧回旋上的球形电极测量视觉皮层中诱发的电位。结果:巩膜缝合线实现了ERP电极到地球的稳定连接。用双极和单极配置的电极记录视觉皮层响应。诱发的反应包括一个早期成分,其峰值在8毫秒左右,一个晚期成分,在50毫秒后达到峰值。引起响应的阈值发生在低至500 microA的电流强度下。通过从诱发的响应幅度数据外推,可计算出低至300 microA的阈值。阴极单极刺激引起的皮层反应阈值比阳极刺激低。结论:ERP电极可以很容易地连接到地球上,并且可以有效地刺激视网膜,引起初级视觉皮层的反应。阈值电荷密度在神经刺激的安全范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号