To evaluate the biocompatibility of a new titanium-tantalum alloy, with qualities superior to titanium alone, for use in oral implantology, fibroblast and epithelial cell lines were grown on plastic, titanium, copper, and titanium-tantalum supports. Studies using scanning electron microscopy, flow cytometry, and cytotoxicity assays were conducted to compare the different supports. Scanning electron microscopic observations showed high densities of fibroblasts and epithelial cells with well-developed attachment systems in the form of cytoplasmic projections. Cell densities were lower on titanium and titanium-tantalum surfaces than on plastic. Cell numbers, as determined by cytotoxicity assays, were significantly higher on plastic than on titanium or titanium-tantalum surfaces while fibroblasts proliferated better than epithelial cells on both metal surfaces. Flow cytometric analyses of cell cycles did not reveal any significant variations in the distribution of cells among the cycle phases on the three materials. We found no differences with regard to the parameters studied between titanium and the titanium-tantalum alloy.
机译:为了评估一种新的钛-钽合金的生物相容性,其质量优于单独的钛,用于口腔种植,在塑料,钛,铜和钛-钽支持物上生长了成纤维细胞和上皮细胞系。进行了使用扫描电子显微镜,流式细胞仪和细胞毒性试验的研究,以比较不同的支持物。扫描电子显微镜观察显示,高密度的成纤维细胞和上皮细胞具有发达的附着系统,呈细胞质突起形式。钛和钛-钽表面的细胞密度低于塑料。通过细胞毒性测定确定的细胞数量,塑料上的细胞数量明显高于钛或钛-钽表面,而成纤维细胞的增殖性能均好于两个金属表面的上皮细胞。细胞周期的流式细胞仪分析未发现这三种材料在周期阶段之间细胞分布的任何显着变化。我们发现在钛和钛-钽合金之间研究的参数方面没有差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号