首页> 外文期刊>Diagnostic cytopathology >The diagnostic reliability of urinary cytology: A retrospective study
【24h】

The diagnostic reliability of urinary cytology: A retrospective study

机译:尿细胞学诊断的可靠性:一项回顾性研究

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was twofold. The first aim was to estimate the diagnostic reliability of urinary cytology for detection and management of urothelial neoplasms by using a specific preserving fluid for sample collection, and the liquid-based thin layer method for specimen preparation, the estimate was based on the correlation between the cytological findings of 10,000 non-hospitalized patients, and their histological diagnoses. A second aim was to compare the reliability of two instruments for thin-layer preparation, i.e., TP2000, TP3000, capable of processing the specimens at very different rates. The preservation of cell structure is ameliorated by the procedure of sample collection and treatment here described. This allows a more accurate reading of LBC slides as shown by: (a) the significant concordance between cytological and histological diagnosis (92%); (b) the significant number of low-grade urothelial carcinomas (20.5%) revealed by urinary cytology and validated by histologic diagnosis; (c) the low rate (8%) of misjudgement of cytological diagnosis reached in this study. The quality of performances of the two instruments tested for thin-layer preparation, i.e., TP2000 and TP3000, is statistically comparable. We recommend the procedure that makes use of preserving fluid for sample collection (cytolyt?) and treatment (preservcyt ?) as here described. We also recommend the use of thin-layer method for specimen preparation since it allows a more uniform distribution of the cells on the support with reduction of overlapping phenomena. Finally, economic considerations suggest the preferential use of Thin Prep 3000.
机译:这项研究的目的是双重的。第一个目的是评估尿液细胞学对尿路上皮肿瘤的检测和处理的诊断可靠性,方法是使用特定的保存液进行样品收集,然后采用液基薄层法进行标本制备,该估计是基于两者之间的相关性。 10,000例非住院患者的细胞学发现及其组织学诊断。第二个目的是比较两种用于薄层制备的仪器(即TP2000,TP3000)的可靠性,该仪器能够以非常不同的速率处理样品。通过本文所述的样品收集和处理程序改善了细胞结构的保存。这样可以更准确地读取LBC载玻片,如下所示:(a)细胞学和组织学诊断之间的显着一致性(92%); (b)尿细胞学检查发现并经组织学诊断证实的大量低度尿路上皮癌(20.5%); (c)在这项研究中,对细胞学诊断的误判率很低(8%)。两种测试用于薄层制备的仪器TP2000和TP3000的性能质量在统计上是可比较的。我们建议按照以下步骤利用保存液进行样品收集(细胞液)和处理(保存液)。我们还建议使用薄层方法进行标本制备,因为它可以使细胞更均匀地分布在支持物上,同时减少重叠现象。最后,出于经济考虑,建议优先使用Thin Prep 3000。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号