BACKGROUND: The importance of transfusing WBC-reduced blood components is widely recognized, as it reduces the risk of alloimmunization and transfusion-transmitted CMV infections. The latest generation of cell separators allows the collection of WBC-reduced apheresis platelet concentrates (APCs). MATERIALS AND METHODS: Consecutive APCs (n = 232) were retrospectively evaluated: 163 collected with the Spectra LRS [leukocyte-reduction system] Version 5.1 (Group A) and 69 with the LRS Turbo Version 7.0 (Group B) (both: COBE BCT). Donor peripheral blood count, procedure data, platelet yield, collection efficiency (CE), and residual WBC count in APCs were recorded. RESULTS: The platelet yield was higher in Group B than in Group A: 5.5 +/- 1.4 versus 4.4 +/- 1.1, p<0.0001; residual WBCs were <5 x 10(6) in 99.4 percent of Group A APCs and in 97.1 percent of Group B APCs. CE was higher in Group B than in Group A: 51.4 +/- 8.7 versus 43.6 +/- 6.3, p<0.0001. Moreover, a correlation between predonation platelet count and platelet yield was observed in both groups. A double product (platelet yield >6.0 x 10(11)) was obtained in 28.9 percent of Group B APCs and in 9.2 percent of Group A APCs. CONCLUSIONS: The Spectra LRS Turbo version 7.0 release showed a better CE and resulted in a higher platelet harvest than did the LRS version 5.1. High predonation platelet counts allow a higher platelet yield.
机译:背景:输注白细胞减少的血液成分的重要性已得到广泛认可,因为它降低了同种免疫和输血传播的巨细胞病毒感染的风险。最新一代的细胞分离器可以收集减少WBC的单采血液成分的血小板浓缩液(APC)。材料与方法:连续APC(n = 232)进行了回顾性评估:使用Spectra LRS [白细胞减少系统] 5.1版(A组)收集了163枚ALP,使用LRS Turbo 7.0版(B组)收集了69枚(均:COBE BCT) )。记录供体外周血计数,程序数据,血小板产量,收集效率(CE)和APC中的残留白细胞计数。结果:B组的血小板产量高于A组:5.5 +/- 1.4对4.4 +/- 1.1,p <0.0001; A组APC的99.4%和B组APC的97.1%的残留白细胞<5 x 10(6)。 B组的CE高于A组:51.4 +/- 8.7对43.6 +/- 6.3,p <0.0001。此外,两组均观察到捐血前血小板计数与血小板产量之间的相关性。在28.9%的B组APC和9.2%的A组APC中获得了双重产物(血小板产率> 6.0 x 10(11))。结论:Spectra LRS Turbo 7.0版比LRS 5.1版显示出更好的CE,并获得更高的血小板收获。捐血前血小板计数高可以提高血小板产量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号