首页> 外文期刊>Thyroid: official journal of the American Thyroid Association >Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: A novel technique
【24h】

Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: A novel technique

机译:超声引导下使用自动抽吸器对临床可疑甲状腺结节进行细针穿刺活检:一种新技术

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. Methods: One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep? method. Results: With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. Conclusions: In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.
机译:背景:细针穿刺活检(FNAB)是一种用于检查可疑甲状腺结节的简单技术。然而,文献报道成功率低。这项前瞻性研究的目的是比较自动抽吸器(在此称为抽吸器3)的临床性能和影响与临床上可疑甲状腺结节FNAB的手动技术的临床性能和影响。方法:使用临床认可的Aspirator 3和手动技术,对119例临床上可疑的甲状腺结节连续的119例患者在同一部位进行两次活检。使用ThinPrep?计数吸出物中的卵泡细胞形成数量和卵泡细胞总数。方法。结果:使用Aspirator 3时,提取的细胞形成的总数和平均数显着高于使用手动技术获得的值(总计:3222 vs. 1951,p = 0.02;平均值:27 vs. 16)。使用Aspirator 3时,活检细胞总数也更高(47,480对23,080,p = 0.005)。总体而言,Aspirator 3在65例活检中表现优异,而手动技术在39例活检中表现优异。结论:就细胞形成和吸出的细胞总数而言,Aspirator 3优于手动技术。此外,吸气器3使用起来更方便并且在针引导中具有更高的精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号