Purpose: VADs could be used for transportation of the great arteries (TGA) and for congenitally corrected transposition (ccTGA) treatment. A cardiovascular numerical model (NM) may offer a useful clinical support in these complex physiopathologies. This work aims at developing and preliminarily verifying a NM of ccTGA and TGA interacting with VADs. Methods: Hemodynamic data were collected at the baseline (BL) and three months (FUP) after apical (atrio-aortic) VAD implantation in a TGA (ccTGA) patient and used in a lumped parameter NM to simulate the patient's physiopathology. Measured (MS) and simulated (SIM) data were compared. Results: MS and SIM data are in accordance at the BL and at FUP. Cardiac output (l/min): BL_m = 2.9 ± 0.4, BL_s = 3.0 ± 0.3; FUP_m = 4.2 ± 0.2, FUP_s = 4.1 ± 0.1. Right atrial pressure (mmHg): BL_m = 21.4 ± 4.1, BL_s = 18.5 ± 4.5; FUP_m = 13 ± 4, FUP_s = 14.8 ± 3.6. Pulmonary arterial pressure (mmHg): BL_m = 56 ± 6.3,BL_s = 57 ± 2, FUP_m = 37.5 ± 7.5, FUP_s = 35.5 ± 5.9. Systemic arterial pressure (mmHg): BL_m = 71 ± 2, BL_s = 74.6 ± 2.1; FUP_m = 84 ± 9, FUP_s = 81.9 ± 9.8. Conclusions: NM can simulate the effect of a VAD in complex physiopathologies, with the inclusion of changes in circulatory parameters during the acute phase and at FUP. The simulation of differently assisted physiopathologies offers a useful support for clinicians.
机译:目的:VAD可用于大动脉(TGA)的运输和先天性纠正性转位(ccTGA)治疗。心血管数值模型(NM)在这些复杂的生理病理学中可能提供有用的临床支持。这项工作旨在开发和初步验证ccTGA和TGA与VAD交互作用的NM。方法:在TGA(ccTGA)患者的根尖(主动脉)VAD植入后的基线(BL)和三个月(FUP)收集血流动力学数据,并将其用于集总参数NM以模拟患者的生理病理学。比较了测量数据(MS)和模拟数据(SIM)。结果:MS和SIM数据符合BL和FUP的要求。心输出量(l / min):BL_m = 2.9±0.4,BL_s = 3.0±0.3; FUP_m = 4.2±0.2,FUP_s = 4.1±0.1。右心房压(mmHg):BL_m = 21.4±4.1,BL_s = 18.5±4.5; FUP_m = 13±4,FUP_s = 14.8±3.6。肺动脉压(mmHg):BL_m = 56±6.3,BL_s = 57±2,FUP_m = 37.5±7.5,FUP_s = 35.5±5.9。全身动脉压(mmHg):BL_m = 71±2,BL_s = 74.6±2.1; FUP_m = 84±9,FUP_s = 81.9±9.8。结论:NM可以模拟VAD在复杂生理病理学中的作用,包括急性期和FUP时循环参数的变化。不同辅助生理病理学的模拟为临床医生提供了有用的支持。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号