During 1998, Eli Lilly and Company conducted a demonstration of commercially available particulate matter continuous emis- sion monitoring systems (PM CEMS) on a liquid hazardous waste incinerator at Lilly's Clinton Labs in Clinton, Indiana. The objective of this demonstration was to evaluate the performance and reliability of PM CEMS in a moisture-saturated flue gas over several months of operation. The demonstration was conducted in two phases designed to conform with Performance Specification 11 (PS 11) of the proposed Hazardous Waste Combustor MACT Rule. Performance was measured by comparing the PM CEMS output with the results of proposed Reference Method 5i developed by EPA during its PM CEMS demonstration test program at Dupont in 1997. During both phases of testing, two PM CEMS were utilized for this test program. These were the Groupe Envir- onnment S. A. (ESA) Model Beta 5M and the Sigrist Photometer AG (Sigrist) Model KTNRM/SIGAR4000. The ESA monitor's operation is based on beta radiation attenuation technology while the Sigrist monitor operation is based on optical light scat- tering technology. Both instruments employ extractive sample systems to condition the moisture-saturated flue gas. Results of the initial phase of the test program concluded that the commercially available PM CEMS evaluated were not ready to be used as compliance tools. Both the beta gauge (ESA) and the light scattering (Sigrist) monitors failed to meet all of the requirements in proposed PS 11 . The objective of the second phase was to implement suggestions made to US EPA and the CEMS vendors regarding improvement to the PM CEMS and calibration procedures in PS ll. In addition, knowledge gained from observing TUV Rheinland successfully calibrate a Sigrist PM CEMS on a HWI at the Eli Lilly Kinsale. Ireland facility was utilized for this second demonstra- tion. Results of the second phase of the test program showed that after a significant learning curve the two extractive PM CEMS evaluated could be calibrated successfully. relative to the requirements of PS ll.
机译:1998年,礼来公司在印第安纳州克林顿的礼来克林顿实验室的液体危险废物焚烧炉上进行了商用颗粒物连续排放监测系统(PM CEMS)的演示。该演示的目的是评估在运行数月后,湿气饱和烟道气中PM CEMS的性能和可靠性。该演示分两个阶段进行,旨在符合提议的危险废物燃烧器MACT规则的性能规范11(PS 11)。通过将PM CEMS的输出与EPA在1997年在杜邦的PM CEMS示范测试程序中开发的参考方法5i的结果进行比较,来测量性能。在这两个测试阶段,该测试程序均使用了两个PM CEMS。这些是Groupe Environment S. A.(ESA)Beta 5M型和Sigrist光度计AG(Sigrist)KTNRM / SIGAR4000型。 ESA监视器的操作基于beta辐射衰减技术,而Sigrist监视器的操作则基于光学散射光技术。两种仪器均采用提取样品系统来调节湿气饱和的烟气。测试程序初始阶段的结果得出结论,评估的市售PM CEMS尚未准备好用作合规工具。贝塔规(ESA)和光散射(Sigrist)监视器均未满足建议PS 11中的所有要求。第二阶段的目标是实施向美国EPA和CEMS供应商提出的有关改进PM CEMS和PS ll中校准程序的建议。此外,通过观察德国莱茵TÜV公司获得的知识成功地在Eli Lilly Kinsale的HWI上校准了Sigrist PM CEMS。爱尔兰的设施被用于第二次示范。测试程序第二阶段的结果表明,经过明显的学习曲线后,可以成功地校准所评估的两个提取式PM CEMS。相对于PS ll的要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号