首页> 外文期刊>Tunnelling and underground space technology >Prediction of smoke back-layering length under different longitudinal ventilations in the subway tunnel with metro train
【24h】

Prediction of smoke back-layering length under different longitudinal ventilations in the subway tunnel with metro train

机译:地铁列车在不同纵向通风条件下烟气回覆长度的预测

获取原文
获取原文并翻译 | 示例
           

摘要

Due to the small width and the large train blockage ratio in subway tunnel, the smoke back-layering will be different from that in the wider road tunnel with small vehicle blockage ratio. In the train blockage region of tunnel, the velocity of longitudinal ventilated air-flow interacting with the back-flowed smoke gas is different from that in the upstream tunnel without train blockage. Then the back-flowed smoke gas might be prevented in the train blockage region with higher ventilation velocity, otherwise it would be stopped in the upstream tunnel without train blockage but with lower ventilation velocity. They were taken into consideration separately and an equivalent fire source was introduced by dividing the dimensionless heat release rate of fire source into two parts in the cases where the smoke back-layering length is longer than metro train length. A series of full-scale numerical simulations are carried out with FDS to investigate the smoke back-layering length in subway tunnel with different train lengths and longitudinal ventilation velocities. The simulation results indicate that the influence of metro train length on the smoke back-layering is great and cannot be ignored any more. A global correlation model is proposed based on the dimensionless analysis and simulation results. (C) 2015 Elsevier Ltd. All rights reserved.
机译:由于地铁隧道的宽度小,火车的堵车率大,因此烟气的反沉积将不同于较宽的道路隧道中的小车阻塞率。在隧道的火车堵塞区域,纵向通风气流与回流的烟气相互作用的速度不同于上游没有火车堵塞的隧道。这样,可以在通风速度较高的火车阻塞区域中防止回流的烟气,否则可以在没有火车阻塞但通风速度较低的上游隧道中将其停止。分别考虑它们,并在烟层的背层长度大于地铁列车长度的情况下,通过将火源的无因次放热率分成两部分来引入等效火源。用FDS进行了一系列的全面数值模拟,以研究不同列车长度和纵向通风速度的地铁隧道中烟气的回覆长度。仿真结果表明,地铁列车长度对烟气反层的影响很大,不能再忽略了。基于无量纲分析和仿真结果,提出了一种全局相关模型。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

  • 来源
  • 作者单位

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

    Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Smoke back-layering; Longitudinal ventilation; Subway tunnel; Metro train; FDS;

    机译:烟层反层;纵向通风;地铁隧道;地铁;FDS;