It has been reported that lattice girders fail due to inadequate steel members. An experimental analysis is herein conducted using material and structural tests to determine the behavior of lattice girders made of B500B and SS400, two representative steel materials. A numerical analysis is also carried out to evaluate the performance of lattice girder in a tunnel. Both the experimental and numerical study indicated that the use of inadequate steel members results in a significant reduction in the working load and can also affect the overall structural stability of the tunnel. Therefore, quality control for lattice girders is of great importance. A review of the quality control systems for lattice girders reveals it to be desirable to introduce an on-site testing method to identify the adequacy of a steel member in the field. Thus, the portable indentation test is suggested as an on-site quality control test for a lattice girder.
机译:据报道,由于钢构件不足,格构梁失效。本文使用材料和结构测试进行实验分析,以确定由两种代表性钢材B500B和SS400制成的桁架梁的性能。还进行了数值分析,以评估隧道中桁架梁的性能。实验和数值研究均表明,使用不足的钢构件会显着降低工作负荷,还会影响隧道的整体结构稳定性。因此,对桁架梁的质量控制非常重要。对桁架梁质量控制系统的回顾表明,有必要引入一种现场测试方法来确定现场钢构件的适当性。因此,建议将便携式压痕测试作为格构梁的现场质量控制测试。