Crosstalk reduction in a polyvinylidene fluoride (PVDF) integrated ultrasound transducer array with a micromachined diaphragm structure is reported. Three sets of linear arrays with nine 1 mm*1 mm elements on dielectric diaphragms have been made. They were fabricated with (1) a solid substrate, (2) a single large diaphragm window underneath the entire array, and (3) a small diaphragm window (SW) for each array element. To estimate crosstalk and fringe field effects in each array, the authors measured each array's angular response in the far field of an unfocused source transducer. A Fourier transform analysis was then performed on the measured data to obtain each array's directivity pattern, which in turn was fitted to theoretical curves based on a crosstalk model. Crosstalk-related parameters have been extracted from curve-fitting and their values show that the array with the SW structure for each element has the least electrical and acoustical crosstalk and fringe field effects.
机译:据报道,具有微加工膜片结构的聚偏二氟乙烯(PVDF)集成超声换能器阵列中的串扰减少。制作了三组线性阵列,在电介质膜片上具有九个1 mm * 1 mm的元件。它们是由(1)固态基板,(2)整个阵列下方的单个大隔膜窗口和(3)每个阵列元件的小隔膜窗口(SW)制成的。为了估计每个阵列中的串扰和边缘场效应,作者在未聚焦的源换能器的远场中测量了每个阵列的角响应。然后对测量的数据进行傅立叶变换分析,以获得每个阵列的方向性图,然后将其拟合到基于串扰模型的理论曲线。已经从曲线拟合中提取了与串扰相关的参数,其值表明,每个元素具有SW结构的阵列具有最小的电和声串扰和边缘场效应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号