The BBL Crystal Anaerobe (ANR) identification system was evaluated, and the results were compared with those from conventional anaerobic methods. We tested 322 clinically significant anaerobic bacteria according to the manufacturer's instructions. The system identified correctly 286 of 322 (88.8%) of the anaerobic bacteria tested. Of these, 263 of 322 (81.7%) were identified correctly on initial testing and 49 were identified correctly only to the genus level; on repeat testing, 23 of 49 (46.9%) were identified correctly to both the genus and the species levels. A total of 26 (8.5%) were misidentified at the species level, and 10 (3.1%) were not identified. Performance characteristics for individual strains varied. The system correctly identified all tested strains of Campylobacter, Desulfomonas, Desulfovibrio, Leptotrichia, Mobiluncus, Peptostreptococcus, Porphyromonas, Provetella, Propionibacterium, Tisierella, and Veillonella and 36 of 37 (97.3%) Actinomyces strains, 42 of 46 (91.3%) B. fragilis group strains, 79 of 103 (76.7%) Clostridium strains, (however, the system failed to identify any of the 7 C. innocuum and 9 C. tetani strains tested), and 8 of 15 (53.3%) Bacteroides strains. This system was easy to use, did not involve the addition of reagents, and was faster than conventional anaerobic procedures. It would be a useful addition to the anaerobe laboratory of most hospitals.
机译:对BBL晶体厌氧菌(ANR)鉴定系统进行了评估,并将结果与​​常规厌氧法的结果进行了比较。我们根据制造商的说明测试了322种临床上重要的厌氧菌。该系统正确地识别了测试的322个厌氧细菌中的286个(88.8%)。其中,在初次测试中正确识别了322个样本中的263个(81.7%),仅在属水平上正确识别了49个;在重复测试中,正确地识别了属和种的49个中的23个(46.9%)。在物种级别总共有26个(8.5%)被误认,而10个(3.1%)没有被识别。各个菌株的性能特征各不相同。该系统正确地鉴定了所有测试的弯曲杆菌,脱硫单孢菌,脱硫弧菌,细小球菌,美孚力克,肽链球菌,卟啉单胞菌,普罗韦氏菌,丙酸杆菌,铁锈菌和韦永氏菌的菌株以及37株放线菌中的36株(占97.3%),占46株(91.3%)。脆弱类群菌株中,梭状芽胞杆菌属菌株中有79株(占76.7%)(但是,系统无法识别所测试的7种无毒梭菌和9种破伤风杆菌中的任何一种),以及15种(53.3%)拟杆菌属菌株中的8种。该系统易于使用,不涉及试剂的添加,并且比常规厌氧程序要快。这将是大多数医院厌氧菌实验室的有用补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号