首页> 外文期刊>Physical Science International Journal >Evaluation of Radiation Doses from Paediatric Chest X-ray Examination at Three Hospitals in South-West Nigeria
【24h】

Evaluation of Radiation Doses from Paediatric Chest X-ray Examination at Three Hospitals in South-West Nigeria

机译:尼日利亚西南三家医院儿科胸部X光检查的放射剂量评估

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The aim of this study is essentially to evaluate radiation doses to paediatric patients who were referred for chest X-ray examination between April, 2015 and December, 2016 in three hospitals South-West, Nigeria. The methodology employed in this study involved measurements based on the use of exposure parameters to determine Entrance Surface Dose (ESD). A total of one hundred (100) paediatric patients randomly chosen were included in this study. ESD was determined from exposure parameters using dose calculation software (Dosecal). The results of this study show that the range of Entrance Surface Doses (ESDs) obtained for 0-1year patient is 38.00-150.00 μGy, for 1-5 years is 43.34-194.00 μGy, for 5-10 years is 74.00-223.00 μGy and for 10-15 years is 87.60-292.00 μGy. The mean ESDs obtained in this study were found to be relatively lower than the ESDs obtained in other previous studies in Nigeria but higher than the recommended reference dose value given by the European guidelines. This indicates that more attention needs to be given to X-ray facilities in the Country and that X-ray departments need to review their practice in terms of training and re-training of radiographers, repeated chest X-ray procedures for paediatrics, calibration of X-ray machines and standardisation of processing chemicals in order to bring dose given to patients to optimum levels. This study has also revealed the need to have dedicated X-ray facilities for paediatrics throughout the country.
机译:这项研究的目的主要是评估从2015年4月至2016年12月在尼日利亚西南三家医院接受X光检查的小儿患者的放射剂量。本研究中使用的方法学涉及基于暴露参数的使用来确定入射表面剂量(ESD)的测量。这项研究总共包括了随机选择的一百(100)名儿科患者。使用剂量计算软件(Dosecal)根据暴露参数确定ESD。这项研究的结果表明,0-1岁患者获得的入口表面剂量(ESDs)范围为38.00-150.00μGy,1-5年获得为43.34-194.00μGy,5-10年获得为74.00-223.00μGy和10-15年的时间为87.60-292.00μGy。发现该研究中获得的平均ESD相对低于尼日利亚其他先前研究中获得的ESD,但高于欧洲指南给出的推荐参考剂量值。这表明需要对该国的X射线设施给予更多的关注,并且X射线部门需要在射线照相师的培训和再培训,儿科反复进行的胸部X射线检查程序, X射线机和处理化学品的标准化,以使患者的剂量达到最佳水平。这项研究还表明,有必要在全国范围内为儿科医师配备专用的X射线检查设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号