For the 7-term general TAN (Through-Attenuator-Network)self-calibration method of a four-sampler vector network analyser (VNA), andfor all derived calibration methods like TLN, TRL, TRM, TAR, or TMN, it isshown that a very simple evaluation procedure of the seven error terms ispossible, even if the Through connection is replaced by a reflectionlessnetwork with known transmission. Expressions for the deviations of themeasured S-parameters of two-port test objects (d.u.t.s) from the truevalues, which are caused by deviations of the modeled S-parameters ofnon-ideal calibration elements ("standards") from their true values, arealso presented. Additionally, it is shown that a TAN calibration is alsopossible in case of unequal reflections of the Network.
机译:对于四采样器矢量网络分析仪(VNA)的7项常规TAN(直通-衰减器网络)自校准方法,以及对于所有派生的TLN,TRL,TRM,TAR或TMN等校准方法,表明即使通过已知传输的无反射网络代替直通连接,也可以对七个误差项进行非常简单的评估。还介绍了由于非理想校准元件(“标准”)的建模S参数与其真实值之间的偏差而导致的两端口测试对象(点)的测量S参数与真实值之间的偏差的表达式。 。另外,表明在网络反射不相等的情况下,也可以进行TAN校准。