It is proposed that the structure of flows in concentration balancing reservoir apparatuses should be modeled by sequentially linked ideal mixing and displacement units. Based on experimental studies of laboratory apparatuses with mixers, an equation is obtained for the description of the dependence of the lag time of the response curve for an input pulse signal on the volume of the apparatus. A mathematical model is obtained for calculating extremal excursions of the concentrations at the exit as a function of the volume and number of sections of the balancing reservoir.
机译:提出应通过顺序连接的理想混合和置换单元对浓度平衡储罐装置中的流动结构进行建模。基于带有混合器的实验室设备的实验研究,获得了一个方程,用于描述输入脉冲信号的响应曲线的滞后时间与设备体积的关系。获得了一个数学模型,用于计算出口处浓度的极值偏移,该值是平衡储液罐容积和断面数量的函数。