Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D–3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called “HipMatch.” However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D–3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D–3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D–3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D–3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D–3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
机译:如果不考虑相对于X射线平板的单个骨盆方向,则基于单一标准前后射线照相的方法来测量全髋关节置换术(THA)之后的杯方向。以前,我们建议使用混合2D–3D配准方案来确定术后髋臼杯的方向,并开发了一个称为“ HipMatch”的面向对象的交叉程序。但是,其准确性和鲁棒性尚未得到充分研究。为了评估可能影响混合2D-3D配准方案确定术后髋臼杯方向的准确性和鲁棒性的潜在因素,我们进行了使用尸体骨盆的全面验证研究。验证研究使用了从相对于X射线板的不同骨盆位置拍摄的9幅X射线照片和两个计算的骨盆层析成像体积,其中一个是在植入杯之前获取的,另一个是在杯植入之后获取的。通过实验确定了可能影响混合2D-3D配准方案准确性和鲁棒性的潜在因素。我们的实验结果表明:(1)基于平片的方法是不准确的; (2)混合2D–3D配准方案有助于提高估计精度; (3)混合2D–3D配准方案即使在射线照相的大部分被遮挡的情况下,也能够可靠而准确地估计出杯的方向; (4)图像分辨率对估计精度影响较小。混合2D–3D配准方案是一种精确而强大的方法,可以测量THA中杯的精确方向。它有望成为临床常规使用中提供基于证据的信息的有价值的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号