首页> 美国卫生研究院文献>Scientific Reports >Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection
【2h】

Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection

机译:熔融温度作图法:一种新的方法用于在样品收集后三小时内快速鉴定未知的致病微生物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel “melting temperature (Tm) mapping method” for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a “match” or “broad match” with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment.
机译:尽早发现病原微生物,对于在感染患者中选择适当的抗菌疗法至关重要。我们在此报告了一种新颖的“解链温度(Tm)作图法”,用于从无菌部位快速鉴定临床样品中的优势细菌。仅使用七套引物,就可以鉴定出100多种细菌。特别地,使用差值,可以识别适合于Tm映射识别的样本。此外,该方法可用于快速诊断临床样品中不存在细菌。我们使用200例疑似脓毒症患者的全血样品测试了Tm定位方法,其中85%(171/200)与检测水平相符的培养结果。根据Tm作图法,总共有130个样品为阴性,根据培养方法,其中98%(128/130)也为阴性。同时,根据Tm定位方法,有70个样品为阳性,在59个适合鉴定的样品中,有100%(59/59)与培养或测序结果表现出“匹配”或“广泛匹配”。这些发现是在全血采集的三个小时内获得的。因此,Tm作图法可用于识别需要及时治疗的传染病。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号