首页> 外文会议>Advances in Cryogenic Engineering: Proceedings of the Cryogenic Engineering Conference >Numerical studies on the effects of hot end temperature on a single-stage multi-bypass type pulse tube cryocooler
【24h】

Numerical studies on the effects of hot end temperature on a single-stage multi-bypass type pulse tube cryocooler

机译:热端温度对单级多旁路脉冲管冷冻室影响的数值研究

获取原文

摘要

The performance of pulse tube cryocooler is affected by the temperature of hot end, which is mainly influenced by the temperature of environment. Effects on a single-stage multi-bypass type pulse tube cryocooler are investigated by means of numerical simulation. For different opening of multi-bypass orifices, the refrigeration performances are studied when hot end temperature changed in a certain range, and some numerical results are provided and analysed. Together with the temperature at cold head and multi-bypass position, the mass flow rate through the multi-bypass orifice is affected significantly by the temperature of hot end, and the optimum opening of multi-bypass orifice decreases with hot end temperature increasing from 240 K to 320 K. Therefore, to select an optimal opening of bypass orifice according to the temperature of operating environment is necessary.
机译:脉冲管冷冻机的性能受热端温度的影响,主要受环境温度的影响。通过数值模拟研究了对单级多旁路脉冲管冷冻机的影响。对于多旁路孔的不同开度,研究了在一定范围内变化的热端温度时研究了制冷性能,并提供了一些数值结果并分析。与冷头的温度和多旁路位置一起,通过多旁路孔口的质量流量受到热端的温度的影响,并且使用的多旁路孔口的最佳打开随着240的热门终端温度而增加。 k至320 k。因此,需要根据操作环境的温度选择旁路孔的最佳开度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号