首页> 外文会议>International conference on fuidization: New horizons in fluidization engineering >DEVELOPMENT OF ELECTRICAL CAPACITANCE VOLUME TOMOGRAPHY (ECVT) AND ELECTROSTATIC TOMOGRAPHY (EST) FOR 3D DENSITY IMAGING OF FLUIDIZED BED SYSTEM
【24h】

DEVELOPMENT OF ELECTRICAL CAPACITANCE VOLUME TOMOGRAPHY (ECVT) AND ELECTROSTATIC TOMOGRAPHY (EST) FOR 3D DENSITY IMAGING OF FLUIDIZED BED SYSTEM

机译:流化床系统的3D密度成像电容体积断层扫描(ECVT)和静电断层摄影(EST)的研制

获取原文

摘要

In this paper, Electrical Capacitance Volume Tomography (ECVT) is used to study a gas-solid fluidized bed system of .1 m ID. The interior flow structures (including the dynamic bed expansion, bubble/void breakage and particle movement) and the charge distribution in a gas-solid fluidized bed are illustrated based on the 3D images obtained from the ECVT.
机译:本文采用电容体积断层扫描(ECVT)研究.1M ID的气固流化床系统。基于从ECVT获得的3D图像示出了内部流动结构(包括动态床膨胀,气泡/空隙和粒子运动)和气体固体流化床中的电荷分布。