首页> 外文会议>International Symposium on Discharges and Electrical Insulation in Vacuum >Investigation of the heat affected volume of CuCr contact material for vacuum interrupters
【24h】

Investigation of the heat affected volume of CuCr contact material for vacuum interrupters

机译:真空灭弧室用CuCr触头材料的热影响量研究

获取原文

摘要

This work is focused on the microstructural changes during switching of simple geometry, butt-type contacts in a demountable vacuum chamber. The heat affected volume in copper-chromium (CuCr) with different chromium (Cr) content and the particle size in the re-solidified area were investigated. It was found that there is only a negligible difference between copper (Cu) with 25 (CC75) and 43 (CC57) wt% Cr. For CC57 a sudden change in the investigated parameters is observed for transferred charges above 35 As and a peak current (Ip) higher than 6 kA. It is assumed that a transition into the arc mode occurs. The results were assessed against published work, in which the switching process was observed using a camera and compared with the development of arc voltage.
机译:这项工作的重点是在可拆卸真空室中简单几何形状,对接型触点切换过程中的微观结构变化。研究了不同铬(Cr)含量的铜铬(CuCr)的热影响体积和再凝固区的粒径。发现在铜(Cu)中含25(CC75)和43(CC57)wt%Cr的铜(Cu)之间的差别可忽略不计。对于CC57,对于高于35 As的转移电荷和高于6 kA的峰值电流(Ip),观察到研究参数的突然变化。假定发生向电弧模式的过渡。根据已发表的作品对结果进行了评估,其中使用摄像机观察了开关过程,并将其与电弧电压的发展进行了比较。