首页> 外文会议>Design and quality for biomedical technologies IX >Spectral Domain Optical Coherence Tomography with Dual-balanced Detection
【24h】

Spectral Domain Optical Coherence Tomography with Dual-balanced Detection

机译:具有双平衡检测的光谱域光学相干断层扫描

获取原文
获取原文并翻译 | 示例

摘要

We developed a spectral domain optical coherence tomography (SD-OCT) system employing dual-balanced detection (DBD) for direct current term suppression and SNR enhancement especially for auto-autocorrelation artifacts reduction. The DBD was achieved by using a beam splitter to building a free-space Michelson interferometer, which generated two interferometric spectra with a phase difference of π. These two phase-opposed spectra were guided to the spectrometer through two single mode fibers of the 8 fiber v-groove array and acquired by ultizing the upper two lines of a three-line CCD camera. We rotated this fiber v-groove array by 1.35 degrees to focus two spectra onto the first and second line of the CCD camera. Two spectra were aligned by optimum spectrum matching algorithm. By subtracting one spectrum from the other, this dual-balanced detection system achieved a direct current term suppression of ~30 dB, SNR enhancement of ~3 dB, and auto-autocorrelation artifacts reduction of ~10 dB experimentally. Finally we respectively validated the feasibility and performance of dual-balanced detection by imaging a glass plate and swine comeal tissue ex vivo. The quality of images obtained using dual-balanced detection was significantly improved with regard to the conventional single-detection (SD) images.
机译:我们开发了一种采用双平衡检测(DBD)的频谱域光学相干断层扫描(SD-OCT)系统,用于直流项抑制和SNR增强,尤其是用于自相关伪像的减少。通过使用分束器构建自由空间迈克尔逊干涉仪来实现DBD,该干涉仪生成了两个相位差为π的干涉光谱。这两个相位相反的光谱通过8光纤v形槽阵列的两个单模光纤被引导到光谱仪,并通过将三行CCD相机的上两行超细化而获得。我们将此光纤v槽阵列旋转了1.35度,以将两个光谱聚焦到CCD相机的第一行和第二行上。通过最佳光谱匹配算法对齐两个光谱。通过从另一个频谱中减去一个频谱,该双平衡检测系统在实验上实现了约30 dB的直流项抑制,约3 dB的SNR增强和约10 dB的自相关伪像降低。最后,我们分别通过对玻璃板和猪彗星组织进行离体成像,分别验证了双平衡检测的可行性和性能。与传统的单检测(SD)图像相比,使用双平衡检测获得的图像质量得到了显着改善。

著录项

  • 来源
  • 会议地点 San Francisco CA(US)
  • 作者单位

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798;

    School of Electrical Electronic Engineering, Nanyang Technological University, Singapore, 639798,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, 639798;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    optical coherence tomography; medical and biological imaging; balanced detection; auto-correlation artifacts reduction; spectrum matching;

    机译:光学相干断层扫描;医学和生物影像学;平衡检测自相关伪像减少;频谱匹配;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号