首页> 外文会议>Computer Distributed Control and Intelligent Environmental Monitoring (CDCIEM), 2012 International Conference on >Transient Processes Time Series Analysis of High-speed Railway Power Traction and Over-voltage Protection
【24h】

Transient Processes Time Series Analysis of High-speed Railway Power Traction and Over-voltage Protection

机译:高速铁路电力牵引和过电压保护的暂态过程时间序列分析

获取原文
获取原文并翻译 | 示例

摘要

Time series analysis method and protective measures were proposed in order to research transient process of over voltage, which caused insulation breakdown and electrical equipment damaged in high-speed railway articulated phase insulator. Equivalent capacitance model of articulated phase insulator is built and variable capacitance dynamic electromagnetic transient model of locomotive and traction power supply network is established, in which some characteristics for electricity voltage initial phase angle and impact on movement are considered. EMTDC simulation experiments are completed for electrified railway of Wuweinan-Jiayuguan, and results verify that neutral line segment method will inhibit transient over voltage.
机译:为了研究过电压的瞬态过程,提出了时间序列分析方法和保护措施。过电压瞬态过程会导致高速铁路铰接相绝缘子的绝缘击穿和电气设备损坏。建立了铰接相绝缘子的等效电容模型,建立了机车和牵引供电网络的可变电容动态电磁暂态模型,其中考虑了电压初始相位角及其对运动的影响。完成了渭南至嘉yu关电气化铁路的EMTDC仿真实验,结果表明中性线段法可以抑制暂态过电压。