The treatment of simulated wastewater containing phenol by electrochemical catalysis oxidation in two-dimensional electro bath is studied. Factors affecting the removal efficiency of hydroquinone are investigated by static experiment, such as electrolyte concentration, electrolysis voltage, air supply and initial pH value. The results showed, with the increasing of electrolyte concentration, the removal rate of hydroquinone first increased, then decreased, with the applied voltage increased, the removal of hydroquinone has be increased. It is helpful for hydroquinone removal in the mild acid, neutral and mild base conditions. The removal rate is highest in the mild base condition. When the electrolyte concentration of Na2SO4 is 0.04mol·L-1, the voltage is 5V, air supply is 80L·h-1, pH is 8.5, the removal rate of hydroquinone is 85.50%.
机译:研究了二维电浴中电化学催化氧化处理含酚模拟废水的方法。通过静态实验研究了影响对苯二酚去除效率的因素,例如电解质浓度,电解电压,空气供应和初始pH值。结果表明,随着电解液浓度的增加,对苯二酚的去除率先增加,然后降低,随着施加电压的增加,对苯二酚的去除率也随之增加。在弱酸,中性和弱碱条件下,有助于去除氢醌。在温和的碱性条件下去除率最高。当Na2SO4的电解质浓度为0.04mol·L-1时,电压为5V,供气量为80L·h-1,pH为8.5,对苯二酚的去除率为85.50%。