This work presents the calculation of the optimal number of measurement cycles used in calibration ofrnthe pressure calibrators. As we know the pressure calibrators are smart transducers [5] having highrnmetrological performances. They are very accurate and more stable than transducers and are used asrnstandards in calibration of the transducers. The specialists from INM have elaborated a calibrationrnmethod, a procedure of calibration [3] and working instructions [4] for pressure calibrators.rnEvaluation of the uncertainty [2] in calibration of the pressure calibrators is very important and needrna good experience. In conformity with [3] the uncertainty of measurement, associate with the result ofrnmeasurement, have to be maximum ? from the tolerate error of the pressure calibrator. In therncalibration of the apparatus with elastic sensing element, the repeatability of the measurements is veryrnimportant and this can be smaller if the number of measurement cycles is bigger. Because the value ofrnrepeatability is multiplied with the Student coefficient we need more number of measurement cycles,rnbut this takes more time and more money. This work describes the calculation of the measurementrnuncertainties, in calibration of the pressure calibrators, for 2, 3 and 6 cycles of measurements. As werncan see in figure 1 , the optimal number of the measurement cycles, take into account the Studentrncoefficient and the condition for the value of uncertainty, is three.
机译:这项工作介绍了用于压力校准器校准的最佳测量循环数的计算。众所周知,压力校准器是具有高计量性能的智能传感器[5]。它们比换能器非常准确且更稳定,并且在校准换能器时被用作标准。 INM的专家已经详细阐述了压力校准器的校准方法,校准程序[3]和操作说明[4]。评估压力校准器的不确定性[2]非常重要,并且需要有良好的经验。根据[3],测量的不确定性与测量结果相关,必须最大。压力校准器的容许误差。在具有弹性感测元件的设备的校准中,测量的可重复性非常重要,并且如果测量周期的数目较大,则可重复性会较小。因为可重复性的值乘以学生系数,我们需要更多的测量周期数,但这需要更多的时间和更多的金钱。这项工作描述了在压力校准器的校准中,对于2、3和6个测量周期的测量不确定度的计算。正如wern可以在图1中看到的那样,考虑到Studentrn系数和不确定性值的条件,最佳的测量周期数为3。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号