1.1This is a fire-test-response standard.1.2This test method is intended to evaluate, under specified fire-exposure conditions, the contribution to room fire growth provided by wall or ceiling materials and assemblies, or both. The method is not intended to evaluate the fire endurance of assemblies or fires originating in the wall assembly. The method provides a means to evaluate the effectiveness of thermal barriers in restricting the contribution of combustible materials in the wall assembly to fire growth in a room fire.1.3This test method, simulating a fire in the corner of a 2420 by 3630 mm (8 by 12 ft) room containing a single open doorway, provides a means to evaluate the relative performance of specified wall and ceiling materials or assemblies when they are used together in the same relationship within an enclosure, and simulating the manner in which they will be used.1.4This test method is intended to evaluate the contribution to fire growth provided by a surface product using a specified ignition source. It shall, however, be noted that the type, position and heat output of the ignition source will considerably influence fire growth. The thermal exposure conditions from the ignition source specified in this method will result in flashover during the 20 min duration for many common finish materials, in particular if specimens are mounted on the walls and the ceiling (standard configuration).1.5This test method provides a means for evaluating wall and ceiling finish materials and assemblies, including panels, tiles, boards, sprayed or brushed coatings, etc. This test method is not intended to evaluate flooring materials or furnishings.1.6This method shall be used in conjunction with GuideE603, which covers instrumentation and the general effect of various parameters, and GuideE2067, which deals with full-scale oxygen consumption calorimetry.1.7The values stated in SI units are to be regarded as the standard. The units given in parentheses are for information only.1.8The text of this standard references notes and footnotes which provide explanatory information. These notes and footnotes (excluding those in figures) shall not be considered as requirements of the standard.1.9This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions.1.10This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.11Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. ====== Significance And Use ======5.1This fire test is applicable to a description of certain fire performance characteristics in appraising wall and ceiling materials, products, or systems under specified fire-exposure conditions in an enclosure. The test indicates the maximum extent of fire growth in a room, the rate of heat release, and if they occur, the time to flashover, and the time to flame extension beyond the doorway following flashover. It determines the extent to which the wall and ceiling materials or assemblies contribute to fire growth in a room and the potential for fire spread beyond the room, under the particular conditions simulated. It does not measure the contribution of the room contents. (SeeAppendix X1, Commentary.)5.2Flashover shall be considered to have occurred when any two of the following conditions have been attained:(a)Heat release rate exceeds 1 MW.(b)Heat flux at the floor exceeds 20 kW/m2.(c)Average upper layer temperature exceeds 600°C.(d)Flames exit doorway.(e)A paper target on the floor auto-ignites.5.2.1Time to flashover shall be the time from start of test until the second condition has been attained.5.3The potential for the spread of fire to other objects in the room, remote from the ignition source, is evaluated by measurements of: (a) the total heat flux incident on the center of the floor, and (b) a characteristic upper level gas temperature in the room.5.4The potential for the spread of fire to objects outside the room of origin is evaluated by the measurement of the rate of heat release of the fire.5.5Measurements of the rate of production of carbon monoxide, carbon dioxide, and visible smoke are taken.5.6The overall performance of the test specimen is visually documented by full-color photographic records. Video taping of the complete fire test is an acceptable alternative to the photographic record. Such records show when each area of the test specimen becomes involved in the fire.5.7In this procedure, the specimens are subjected to a specific set of laboratory fire test exposure conditions. If different test conditions are substituted or the anticipated end-use conditions are changed, it is not known whether it is possible by use of this test to predict changes in the performance characteristics measured. Therefore, the results are strictly valid only for the fire test exposure conditions described in this procedure.
机译:1.1这是火灾测试响应标准。1.2本试验方法旨在评估在规定的火灾暴露条件下,墙体或天花板材料和组件或两者对房间火灾增长的贡献。该方法不用于评估组件的耐火极限或源自墙体组件的火灾。该方法提供了一种方法,用于评估隔热层在限制墙体组件中可燃材料对房间火灾增长的贡献方面的有效性。1.3本试验方法模拟了一个2420×3630 mm(8×12 ft)房间角落的火灾,该房间包含一个开放的门口,提供了一种方法来评估指定的墙壁和天花板材料或组件在一个封闭空间内以相同关系一起使用时的相对性能,并模拟其使用方式。1.4本试验方法旨在评估使用指定点火源的表面产品对火灾增长的贡献。然而,应注意,点火源的类型、位置和热输出将显著影响火灾增长。本方法中规定的点火源的热暴露条件将导致许多常见饰面材料在20分钟内发生闪络,特别是如果样品安装在墙上和天花板上(标准配置)。1.5本试验方法提供了一种评估墙壁和天花板饰面材料和组件的方法,包括面板、瓷砖、木板、喷涂或拉丝涂层等。本试验方法不用于评估地板材料或家具。1.6该方法应与指南一起使用E603,包括仪器和各种参数的一般影响,以及指南E2067年,它涉及全尺寸耗氧量热法。1.7以国际单位制表示的数值应视为标准。括号中给出的单位仅供参考。1.8本标准的文本引用了提供解释信息的注释和脚注。这些注释和脚注(不包括图中的注释和脚注)不应视为本标准的要求。1.9本标准用于测量和描述材料、产品或组件在受控条件下对热量和火焰的响应,但其本身并不包含火灾所需的所有因素-实际火灾条件下材料、产品或组件的危险或火灾风险评估。1.10本标准并非旨在解决与其使用相关的所有安全问题(如有)。本标准的用户有责任在使用前制定适当的安全和健康实践,并确定监管限制的适用性。1.11防火测试本身就很危险。在进行这些测试时,应采取适当的人员和财产保护措施。====意义和用途======5.1本耐火试验适用于在特定火灾下评估墙壁和天花板材料、产品或系统的某些耐火性能特征的描述-外壳中的暴露条件。该测试表明了房间内火灾增长的最大程度、热释放速率,以及如果发生闪络,闪络时间和闪络后火焰延伸到门口以外的时间。它确定了在模拟的特定条件下,墙和天花板材料或组件对房间内火灾增长的贡献程度以及火灾蔓延到房间外的可能性。它不衡量房间内容的贡献。(参见附录X1,评论。)5.2当达到以下任何两种条件时,应认为发生了闪络:(a)热释放速率超过1 MW。(b)地板热通量超过20 kW/m2..(c)上层平均温度超过600°C。(d)火焰从门口熄灭。(e)地板上的纸靶自动点火。5.2.1闪络时间应为从试验开始到达到第二个条件的时间。5.3通过测量以下各项来评估火灾蔓延至房间内远离点火源的其他物体的可能性:(一)地板中心入射的总热通量,以及(b)房间内的特征上层气体温度。5.4通过测量火灾热释放速率来评估火灾蔓延到起源房间外物体的可能性。5.5测量一氧化碳、二氧化碳和可见烟雾的产生速率。5.6通过全彩摄影记录直观记录试样的整体性能。完整火灾试验的录像是摄影记录的可接受替代方案。这些记录显示了试样的每个区域何时卷入火灾。5.7在该程序中,样本经受一组特定的实验室火灾试验暴露条件。如果替换了不同的测试条件或预期的最终使用条件发生了变化,则不知道是否可以通过使用该测试来预测所测性能特性的变化。因此,结果仅在本程序中描述的火灾试验暴露条件下严格有效。

著录项

  • 标准号ASTM E2257-16

    标准状态历史

  • 发布单位或类别美国-美国材料与试验协会(US-ASTM);

    发布日期2016-02-01

  • 实施日期

    废止日期

  • CCS分类

    ICS分类13.220.50 消防 - 建筑材料和构件的阻燃性

  • 其他编号ASTM E2257-16

  • 起草单位

  • 起草人

  • 归口单位 E05.21

关联关系

  • 代替如下标准
  • 被如下标准代替
  • 引用下列标准
  • 采用如下标准
  • 0.ASTM E2257-13a

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号