首页> 外文OA文献 >Discrimination accuracy between real and sham needles using the Park sham device in the upper and lower limbs.
【2h】

Discrimination accuracy between real and sham needles using the Park sham device in the upper and lower limbs.

机译:使用Park假设备在上肢和下肢中区分真针和假针。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective To evaluate the blinding effectiveness of the Park sham acupuncture device using participants' ability to discriminate between the real and sham acupuncture needles in the (1) upper limb (TE points) compared with pure guessing and (2) lower limb (BL points) compared with pure guessing. Methods 20 healthy acupuncture-naïve university students and staff were recruited through convenience sampling. Participants made Yes-No judgements on whether the real or sham needle was administered to four TE acupoints on the dominant upper limb, and four acupoints along the BL meridian on the dominant lower limb. The proportion of correct judgements, P(C), for each participant was calculated to indicate the discrimination accuracy of participants in distinguishing between the real and sham needles. Separate P(C) were computed for the upper limb acupoints and lower limb acupoints. The data were also pooled to calculate a P(C) for a combination of both body regions. Results The participants' discrimination accuracy between the real and sham needles was not statistically signifi cant from P(C)=0.5 (chance level) for the lower limb alone and combined body regions' acupoint comparisons (lower limb: t 19=0.00, unadjusted p=1.00; combined: t19=1.75, unadjusted p=0.10). However, the participants' discrimination accuracy was statistically signifi cant from P(C)=0.5 for the upper limb acupoints alone comparison (t 19=2.36, unadjusted p=0.03). Conclusions This study showed that the Park sham device is more likely to blind participants in differentiating between the real and sham needles in the lower limb (BL meridian) acupoints than in the upper limb (TE meridian). However, the participants' ability to differentiate between the needle types for the upper limb acupoints was signifi cantly different from chance levels
机译:目的利用参与者辨别(1)上肢(TE点)与纯猜测和(2)下肢(BL点)的实针和假针的能力,评估Park假针刺装置的致盲效果。与纯猜测相比。方法通过方便抽样方法,招募了20名健康的针灸初学者大学生和工作人员。参与者对是对占主导地位的上肢的四个TE穴位,还是占占主导地位的下肢的BL经络的四个穴位进行了实针或假针的判断是-否。计算每个参与者正确判断的比例P(C),以表明参与者在区分真针和假针时的辨别准确性。分别计算上肢和下肢的P(C)。还汇总了数据以计算两个身体区域的组合的P(C)。结果从单独的下肢和合并的身体部位的穴位比较(下肢:t 19 = 0.00,未经调整)的P(C)= 0.5(机会水平),参与者的真实针和假针之间的辨别准确性在统计学上并不显着p = 1.00;合计:t19 = 1.75,未经调整的p = 0.10)。然而,对于单独的上肢穴位比较,参与者的辨别准确性从P(C)= 0.5有统计学意义(t 19 = 2.36,未经调整的p = 0.03)。结论这项研究表明,Park假手术装置较之于上肢(TE子午线),在区分下肢(BL子午线)穴位的真针和假针时,更容易使参与者盲目。但是,参与者区分上肢穴位的针头类型的能力与机会水平明显不同

著录项

  • 作者单位
  • 年度 2011
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号