Scanning beyond the limits of standard OCT with a Fourier domain optical coherence tomography integrated into a slit lamp: the SL SCAN-1

机译:使用裂隙灯中集成的傅立叶域光学相干断层扫描技术扫描超出标准OCT的范围:SL SCAN-1

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose With a new Fourier domain optical coherence tomography (FD OCT) device, SL SCAN-1 (Topcon Europe Medical BV, Capelle a/d IJssel, The Netherlands), integrated into a slit-lamp OCT, scans can be obtained through a handheld lens. The necessary adjustment of the reference arm is possible by fast Z-alignment. This study was performed to prove the capability of SL SCAN-1 to scan through a three-mirror contact lens, scanning the peripheral retina and anterior chamber angle. Methods Different representative pathologies of the peripheral retina and anterior chamber were simultaneously observed and scanned with the SL SCAN-1. The scans of peripheral retinal lesions were obtained both through a handheld lens and through a three-mirror contact lens. The anterior chamber angle was scanned directly with the SL SCAN-1 in anterior mode, and through the gonio-mirror of a three-mirror contact lens with the SL SCAN-1 in posterior mode. Results OCT scans could be obtained with the SL SCAN-1 of the peripheral retina through both, a common handheld lens and a three-mirror contact lens. The scans obtained through a three-mirror contact lens were of better quality, visualizing details of the different layers of the retina more clearly. The scans of the anterior chamber, obtained through the gonio-mirror of a three-mirror contact lens, visualized the open anterior chamber angle, with details of fine structures. Conclusions The SL SCAN-1 is a unique FD OCT system, which is able to scan not only the posterior pole and anterior segment but also the anterior chamber angle and the more peripheral retina. These four modalities combined into one device could make the SL SCAN-1 a very powerful aid in daily practice. Eye (2011) 25, 97-104; doi: 10.1038/eye.2010.162; published online 12 November 2010
机译:目的借助集成在裂隙灯OCT中的新型傅立叶域光学相干层析成像(FD OCT)设备SL SCAN-1(Topcon Europe Medical BV,Capelle a / d IJssel,荷兰),可以进行扫描镜片。通过快速Z轴对齐可以对参考臂进行必要的调整。进行这项研究是为了证明SL SCAN-1能够扫描三镜隐形眼镜,扫描周围视网膜和前房角。方法用SL SCAN-1同时观察和扫描周围视网膜和前房的不同代表性病变。既可通过手持式镜片也可通过三镜隐形眼镜获得周围视网膜病变的扫描图。前房角通过SL SCAN-1直接在前模式下扫描,并通过三镜隐形眼镜的角镜在SL SCAN-1后模式下进行扫描。结果可以通过普通手持镜和三镜隐形眼镜,通过周围视网膜的SL SCAN-1获得OCT扫描。通过三镜隐形眼镜获得的扫描质量更高,可以更清晰地看到视网膜不同层的细节。通过三镜角膜接触镜的角膜镜对前房进行扫描,可以看到前房开放角度,并具有精细的结构细节。结论SL SCAN-1是一种独特的FD OCT系统,不仅可以扫描后极和前段,还可以扫描前房角和更多的周边视网膜。将这四种模式组合到一个设备中,可使SL SCAN-1在日常实践中成为非常强大的帮助。 Eye(2011)25,97-104; doi:10.1038 / eye.2010.162;在线发布于2010年11月12日

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号