The electrochemical behavior of steel reinforcement in conditions of corrosion and cathodic protection (CP) was studied, using electrochemical impedance spectroscopy (EIS) and compared to reference (non-corroding) conditions. Polarization resistance (PR) method and potentio-dynamic polarization (PDP) were employed as well, in addition to AC 2 pin electrical resistance monitoring, thus deriving a comparison of the involved parameters. It was found out that EIS is readily applicable for evaluating electrochemical behavior of the steel surface not only for corroding or passive state, but also in conditions of CP, although the interpretation of derived parameters is not straightforward and is related to the properties of the product layers, formed on the steel surface in the different conditions. The evaluation of the electrochemical behavior of the steel surface, should take into account the crystallinity, morphology and composition of the surface layers, which were investigated by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX).
机译:使用电化学阻抗谱(EIS)研究了钢筋在腐蚀和阴极保护(CP)条件下的电化学行为,并将其与参考(非腐蚀)条件进行了比较。除监视AC 2引脚电阻外,还采用了极化电阻(PR)方法和电位动态极化(PDP),从而得出了相关参数的比较。已经发现,EIS不仅适用于腐蚀或钝化状态,还适用于CP条件下,都可用于评估钢表面的电化学行为,尽管导出参数的解释并不直接,并且与产品的性能有关。在不同条件下在钢表面形成的涂层。评估钢表面的电化学行为时,应考虑到表面层的结晶度,形态和组成,并通过扫描电子显微镜(SEM)和能量色散X射线分析(EDAX)对其进行了研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号