PURPOSE: The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. MATERIALS AND METHODS: One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7 50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4 50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. RESULTS: The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions >or=10 mm was 86% in group 1 and 97% in group 2 (p = 0.355). Patient burden from diarrhoea significantly decreased for patients in group 2. CONCLUSIONS: One-day preparation with meglumine ioxithalamate results in an improved patient acceptability compared with 2-day preparation and has a comparable, excellent image quality and good diagnostic performance
机译:目的:本研究的目的是比较粪便潜血试验(FOBT)阳性筛查人群的1天和2天碘肠制剂用于CT结肠造影。材料与方法:连续对100例患者行CT结肠造影和结肠镜检查,并伴有节段性失明。前50例患者(第1组)在CT结肠造影前2天开始摄入7 50 ml碘造影剂。后50名患者(第2组)在CT结肠造影术前1天开始摄入4份50 ml碘造影剂。进行每个结肠段残余粪便衰减和均质性的测量,并进行主观评价标记质量(1-5级)。独立地,两名评论者进行了息肉和癌的检测。结果:第1组和第2组的标记密度分别为638 HU和618 HU(p = 0.458),同质性分别为91和86 HU(p = 0.145)。组1中90%的分组和组2中91%的标记质量被评为5级(优秀)(p = 0.749)。在第1组中,对于大于或等于10 mm的病变,平均每息肉敏感性为86%,在第2组中为97%(p = 0.355)。第2组患者的腹泻患者负担显着降低。结论:与2天制剂相比,使用葡甲胺碘羟丙酸酯的一日制剂可提高患者的可接受性,并且具有可比的出色图像质量和良好的诊断性能

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号