In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions

机译:以传统方式和数字方式获得完整牙弓牙齿印模的体内精度

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

STATEMENT OF PROBLEM: Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. PURPOSE: The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. MATERIAL AND METHODS: Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; digitized scannable vinylsiloxanether, VSES-D; and irreversible hydrocolloid, ALG) and 7 digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; Lava COS, LAV; Lava True Definition Scanner, T-Def; 3Shape Trios, TRI; and 3Shape Trios Color, TRC) techniques. Impressions were made 3 times each in 5 participants (n=15). The impressions were then compared within and between the test groups. The cast surfaces were measured point-to-point using the signed nearest neighbor method. Precision was calculated from the (90%-10%)/2 percentile value. RESULTS: The precision ranged from 12.3 μm (VSE) to 167.2 μm (ALG), with the highest precision in the VSE and VSES groups. The deviation pattern varied distinctly according to the impression method. Conventional impressions showed the highest accuracy across the complete dental arch in all groups, except for the ALG group. CONCLUSIONS: Conventional and digital impression methods differ significantly in the complete-arch accuracy. Digital impression systems had higher local deviations within the complete arch cast; however, they achieve equal and higher precision than some conventional impression materials.
机译:问题陈述:近年来,数字印模系统得到了重大发展,但是很少有研究研究该技术在体内的准确性,特别是与传统印模技术相比。目的:这项体内研究的目的是研究传统和数字方法对完整牙弓印象的准确性。材料和方法:使用5种常规(聚醚,POE,乙烯基硅氧烷,VSE;直接可扫描乙烯基硅氧烷,VSES;数字化可扫描乙烯基硅氧烷,VSES-D;以及不可逆水胶体,ALG)和7种数字(CEREC Bluecam,CER)获得完整的拱形印模; CEREC Omnicam,OC; Cadent iTero,ITE; Lava COS,LAV; Lava True Definition Scanner,T-Def; 3Shape Trios,TRI; 3Shape Trios Color,TRC)技术。在5位参与者中,每次印象3次(n = 15)。然后在测试组内和测试组之间比较印象。使用符号最近邻法对铸件表面进行点对点测量。精度是根据(90%-10%)/ 2个百分位数计算的。结果:精度范围从12.3μm(VSE)到167.2μm(ALG),在VSE和VSES组中精度最高。偏差模式根据压印方法明显不同。常规印模显示,除ALG组外,所有组中整个牙弓的准确性最高。结论:常规和数字印模方法在完整拱形精度上存在显着差异。数字印象系统在完整的拱形模型中具有较高的局部偏差;但是,与某些传统印模材料相比,它们具有相同且更高的精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号