首页> 外文OA文献 >Condensation and evaporation of R32/R1234ze(E) and R744/R32/R1234ze(E) flow in horizontal microfin tubes
【2h】

Condensation and evaporation of R32/R1234ze(E) and R744/R32/R1234ze(E) flow in horizontal microfin tubes

机译:水平微管中R32 / R1234ze(E)和R744 / R32 / R1234ze(E)流动的冷凝和蒸发

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The heat transfer characteristics of the low global warming potential refrigerant mixture R744/R32/R1234ze(E) in a horizontal microfin tube were investigated in this study. The condensation heat transfer coefficient of R744 /R32/R1234ze(E) (9/29/62 mass %) is somewhat lower than that of other mixtures, e.g., R744/R32/R1234ze(E) (4/43/53 mass %) and R32/R1234ze(E) (40/60 mass %) and (30/70 mass %), at an average saturation temperature of 40◦C, mass flux of 200 kg m−2s−1, and heat flux of 10 kWm−2. The temperature glides of R744/R32/R1234ze(E) (9/29/62 mass%) and (4/43/53 mass %) and R32/R1234ze(E) (30/70 mass %) and (40/60 mass %) are 18, 11, 10, and 8 K, respectively, at 40◦C. Likewise, the magnitude of the heat transfer coefficient decrease is strongly affected by the temperature glide. The data for the evaporation heat transfer coefficient indicated similar effects of the temperature glide. At an average saturation temperature of 10◦C, the evaporation heat transfer coefficient of R744/R32/R1234ze(E) (9/29/62 mass %) is slightly lower than that of other mixtures. The temperature glides of R744/R32/R1234ze(E) (9/29/62 mass %) and (4/43/53 mass%) and R32/R1234ze(E) (30/70 mass %) and (40/60 mass %) are 22, 13, 11, and 9 K, respectively. The pressure gradients of these refrigerants are almost equal, and the difference is within the measurement uncertainty. The experimental pressure gradient agrees well with the predictions proposed for single components.
机译:研究了水平微翅片管中低全球变暖潜能的制冷剂混合物R744 / R32 / R1234ze(E)的传热特性。 R744 / R32 / R1234ze(E)(9/29/62质量%)的冷凝传热系数略低于其他混合物,例如R744 / R32 / R1234ze(E)(4/43/53质量%) )和R32 / R1234ze(E)(40/60质量%)和(30/70质量%),平均饱和温度为40°C,质量通量为200 kg m-2s-1,热通量为10 kWm-2。 R744 / R32 / R1234ze(E)(9/29/62质量%)和(4/43/53质量%)和R32 / R1234ze(E)(30/70质量%)和(40/60质量%)在40°C时分别为18 K,11、10和8 K.同样,传热系数下降的幅度也受到温度滑移的强烈影响。蒸发传热系数的数据表明温度滑移的类似影响。在10°C的平均饱和温度下,R744 / R32 / R1234ze(E)的蒸发传热系数(9/29/62质量%)略低于其他混合物。 R744 / R32 / R1234ze(E)(9/29/62质量%)和(4/43/53质量%)和R32 / R1234ze(E)(30/70质量%)和(40/60质量%)分别为22、13、11和9K。这些制冷剂的压力梯度几乎相等,并且差异在测量不确定度之内。实验压力梯度与针对单个组件提出的预测非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号