The authors have researched on the design requirement of shear panel damper. In this paper, we performed cyclic loading test of shear-panel-damper with stiffeners, and as well as consider the required rigidity of the stiffeners, collect data on the faitigue relationship of panel, and comparison with the data of non-stiffening panel. As a result, for the panel with stiffeners, fatigue life tends to decrease by cracks are easily occur at the stiffener weld. The relationship of the optimum stiffener flexural rigidity ratio and the stiffener flexural rigidity ratio may alleviate the coefficient to 3.0 or less. Then, within this experimental range, with respect to the panel with stiffeners, by the panle buckling prediction region, it can better determine the presence or absence of pinching occurs. These results showed the validity and effectiveness of the expressions and the method.
机译:作者对剪力板阻尼器的设计要求进行了研究。在本文中,我们进行了带加强筋的剪力板-阻尼器的循环荷载试验,并考虑了加强筋的所需刚度,收集了面板的疲劳关系数据,并与非加强板的数据进行了比较。结果,对于具有加强件的面板,疲劳寿命趋于降低,因为在加强件焊缝处容易发生裂纹。最佳的加劲肋抗弯刚度比和加劲肋抗弯刚度的关系可使系数减小到3.0或更小。然后,在该实验范围内,对于具有加强板的面板,通过板屈曲预测区域,可以更好地确定是否存在捏合。这些结果表明了表达式和方法的有效性和有效性。