摘要

The rapid development of photovoltaic (PV) systems in electrical grids brings new challenges in the control and operation of power systems. A considerable share of already installed PV units are small-scale units, usually connected to low voltage (LV) distribution systems that were not designed to handle a high share of PV power. This paper provides an in-depth review of methods and strategies proposed to prevent overvoltage in LV grids with PV, and discusses the effectiveness, advantages, and disadvantages of them in detail. Based on the mathematical framework presented in the paper, the overvoltage caused by high PV penetration is described, solutions to facilitate higher PV penetration are classified, and their effectiveness, advantages, and disadvantages are illustrated. The investigated solutionsinclude the grid reinforcement, electrical energy storage application, reactive power absorption by PV inverters, application of active medium voltage to low voltage (MV/LV) transformers, active power curtailment, and demand response (DR). Coordination between voltage control units by localized, distributed, and centralized voltage control methods is compared using the voltage sensitivity analysis. Based on the analysis, a combination of overvoltage prevention methods and coordination between voltage control units can provide an efficient and reliable solution to increase the PV hosting capacity of LV grids. ½½
机译:电网中光伏(PV)系统的快速发展给电力系统的控制和运行带来了新的挑战。在已经安装的PV装置中,相当一部分是小型装置,通常连接到低压(LV)配电系统,而低压配电系统的设计不能处理大部分PV功率。本文深入探讨了为防止带有PV的LV电网中过电压而提出的方法和策略,并详细讨论了它们的有效性,优点和缺点。基于本文提出的数学框架,描述了由高PV渗透引起的过电压,对促进高PV渗透的解决方案进行了分类,并说明了其有效性,优点和缺点。研究的解决方案包括电网加固,电能存储应用,PV逆变器吸收无功功率,对低压(MV / LV)变压器施加有功中压,有功功率削减和需求响应(DR)。使用电压敏感度分析比较了通过局部,分布式和集中式电压控制方法进行的电压控制单元之间的协调。根据分析,将过压预防方法与电压控制单元之间的协调结合起来可以提供一种有效且可靠的解决方案,以增加低压电网的光伏承载能力。 ½½

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号