This paper presents an analysis and comparison of isolated topologies for bidirectional fuel cell systems. The analyzed topologies are the dua l active bridge (DAB) and the isolated full bridge boost converter (IFBBC). The analysis is performed based on the component stress factor (CSF). Results highlight that the DAB has lower CSF than the IFBBC for narrow converter operating points. On the other hand the IFBBC presents a more homogeneous CSF over the entire converter operating range. Finally, experimental results obtained from a 30-80 V 80 A 6 kW 40 kHz IFBBC are presented. The converter achieves efficiencies up to 98.2% and 97.45% depending on the converter power flow.
机译:本文介绍了双向燃料电池系统隔离拓扑的分析和比较。分析的拓扑是双有源桥(DAB)和隔离式全桥升压转换器(IFBBC)。基于组件应力因子(CSF)进行分析。结果表明,对于狭窄的转换器工作点,DAB的CSF低于IFBBC。另一方面,IFBBC在整个转换器工作范围内呈现出更均匀的CSF。最后,介绍了从30-80 V 80 A 6 kW 40 kHz IFBBC获得的实验结果。取决于转换器的功率流,转换器可实现高达98.2%和97.45%的效率。