首页> 外文OA文献 >Introducing a standard method for experimental determination of the solvent response in laser pump, x-ray probe time-resolved wide-angle x-ray scattering experiments on systems in solution
【2h】

Introducing a standard method for experimental determination of the solvent response in laser pump, x-ray probe time-resolved wide-angle x-ray scattering experiments on systems in solution

机译:介绍一种标准方法,用于实验测定激光泵中的溶剂响应,X射线探针时间分辨广角X射线散射实验在溶液中的系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In time-resolved laser pump, X-ray probe wide-angle X-ray scattering experiments on systems in solution the structural response of the system is accompanied by a solvent response. The solvent response is caused by reorganization of the bulk solvent following the laser pump event, and in order to extract the structural information of the solute, the solvent response has to be treated. Methodologies capable of doing so include both theoretical modelling and experimental determination of the solvent response. In the work presented here, we have investigated how to obtain a reproducible solvent response-the solvent term-experimentally when applying laser pump, X-ray probe time-resolved wide-angle X-ray scattering. The solvent term describes difference scattering arising from the structural response of the solvent to changes in the hydrodynamic parameters: pressure, temperature and density. We present results based on NIR and dye mediated solvent heating, and demonstrate that the solvent response is independent of the heating method. The NIR heating is shown to be rendered unusable by higher order effects under certain experimental conditions, while the dye mediated solvent heating is demonstrated to exhibit first order behaviour with respect to the amount of energy deposited in the solution. We introduce a standardized method for recording solvent responses in laser pump, X-ray probe time-resolved X-ray wide-angle scattering experiments by using dye mediated solvent heating. Furthermore, we have generated a library of solvent terms, which can be used to describe the solvent term in any TRWAXS experiment, and made it available online.
机译:在时间分辨激光泵中,在溶液中的系统上进行X射线探针广角X射线散射实验时,系统的结构响应伴随着溶剂响应。溶剂响应是由激光泵事件后本体溶剂的重组引起的,为了提取溶质的结构信息,必须处理溶剂响应。能够做到这一点的方法包括溶剂响应的理论建模和实验确定。在本文介绍的工作中,我们研究了如何获得可重现的溶剂响应-实验性地(当使用激光泵,X射线探针时间分辨广角X射线散射时使用溶剂项)。溶剂术语描述了由于溶剂对流体力学参数(压力,温度和密度)变化的结构响应而引起的差异散射。我们目前基于NIR和染料介导的溶剂加热的结果,并证明溶剂响应与加热方法无关。在某些实验条件下,NIR加热由于较高阶的效应而变得无法使用,而染料介导的溶剂加热则相对于溶液中沉积的能量表现出一级行为。我们介绍了一种用于记录激光泵中溶剂响应的标准化方法,通过使用染料介导的溶剂加热来进行X射线探针时间分辨X射线广角散射实验。此外,我们生成了溶剂术语库,可用于描述任何TRWAXS实验中的溶剂术语,并使其在线可用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号