首页> 外文OA文献 >Performance of 20:1 multiplexer for large area charge readouts in directional dark matter TPC detectors
【2h】

Performance of 20:1 multiplexer for large area charge readouts in directional dark matter TPC detectors

机译:用于大面积电荷读数的20:1多路复用器的性能   定向暗物质TpC探测器

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

More target mass is required in current TPC based directional dark matterdetectors for improved detector sensitivity. This can be achieved by scaling upthe detector volumes, but this results in the need for more analogue signalchannels. A possible solution to reducing the overall cost of the chargereadout electronics is to multiplex the signal readout channels. Here, wepresent work on an expanded LMH6574 multiplexer system with a capability ofreducing the number of readouts in such TPC detectors by a factor of 20.Results indicate that the important charge distribution asymmetry along anionization track is retained after multiplexed signals are demultiplexed.
机译:当前基于TPC的定向暗物质探测器需要更多的目标质量,以提高探测器的灵敏度。这可以通过按比例增加检测器的体积来实现,但这导致需要更多的模拟信号通道。降低电荷读出电子设备总成本的一种可能解决方案是多路复用信号读出通道。在这里,我们介绍了一种扩展的LMH6574多路复用器系统的工作,该系统具有将此类TPC检测器中的读数数量减少20倍的能力。结果表明,在多路复用信号多路分解后,沿阴离子化轨道的重要电荷分布不对称性得以保留。