首页> 外文OA文献 >Photon Detection Efficiency Measurements of the VERITAS Cherenkov Telescope Photomultipliers after four Years of Operation
【2h】

Photon Detection Efficiency Measurements of the VERITAS Cherenkov Telescope Photomultipliers after four Years of Operation

机译:VERITas Cherenkov的光子探测效率测量   经过四年的运行后,望远镜光电倍增管

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The photon detection efficiency of two sets of R10560-100-20 superbialkaliphotomultiplier tubes from Hamamatsu were measured between 200 nm and 750 nm toquantify a possible degradation of the photocathode sensitivity after fouryears of operation in the cameras of the VERITAS Cherenkov telescopes. A sampleof 20 photomultiplier tubes, which was removed from the telescopes was comparedwith a sample of 20 spare photomultiplier tubes, which had been kept instorage. It is found that the average photocathode sensitivity marginallyincreased below 300 nm and dropped by 10% to 30% above 500 nm. The averagephotocathode sensitivity folded with the Cherenkov spectrum emitted byparticles in air showers, however, reveals a consistent detection yield of18.9+/-0.2% and 19.1+/-0.2% for the sample removed from the telescope and thespare sample, respectively.
机译:在VERITAS Cherenkov望远镜的相机中运行四年后,测量了Hamamatsu的两套R10560-100-20超bialkali光电倍增管的光子检测效率,以量化光阴极灵敏度可能下降的情况。将从望远镜中取出的20个光电倍增管样品与20个备用光电倍增管样品进行了比较,这些样品已保存。已发现,平均光阴极灵敏度在300 nm以下略有增加,而在500 nm以上则下降10%至30%。然而,从淋浴器和备用样品中取出的样品,平均阴极的感光度随颗粒发射的Cherenkov光谱而折叠,显示出一致的检测产率,分别为18.9 +/- 0.2%和19.1 +/- 0.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号